Impact of SPECT and integrated low-dose CT after radioiodine therapy on the management of patients with thyroid carcinoma
- 1 December 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 25 (12) , 1177-1182
- https://doi.org/10.1097/00006231-200412000-00004
Abstract
Aim To determine the value of single photon emission computed tomography (SPECT) with integrated low-dose computed tomography (CT) for the interpretation of inconclusive foci in planar 131I whole-body scans after radioiodine therapy. Methods Twenty-five patients with inconclusive findings in planar scanning after ablative radioiodine therapy (3.7 GBq 131I) due to differentiated thyroid cancer were included. SPECT/CT of the region in question was performed with the Millennium VG Hawkeye (GE Medical Systems). SPECT with and without CT fusion were evaluated by two blinded independent nuclear medicine physicians in a consensus reading (including visual plausibility control). Each focus was judged according to its topographical assignment and clinical interpretation. With regard to therapeutic relevance, this information was evaluated in a focus based and patient based analysis. All evaluations used a binary ranking system. Focus assignments were compared to clinical and imaging follow-up. Results Forty-one lesions were observed in 25 patients. According to follow-up, 17/41 (41%) foci were caused by thyroid residue, 13/41 (32%) were caused by metastases, and 11/41 (27%) were not malignant. Of these foci, a SPECT/CT consensus reading assigned 39 (95%) correctly, as fused images of two foci did not pass the visual plausibility control (excluding one patient due to misregistration). For the remaining 39 foci, improved anatomical assignment by SPECT/CT was seen in 17/39 (44%) cases. Conclusions The changed interpretation of 15/39 (38%) foci would have been relevant for therapy in the focus based analysis. In the patient based analysis the information was still therapeutically relevant in 6/24 (25%) patients. Furthermore, plausibility control is also crucial in SPECT/CT image fusion in order to rule out artifacts.Keywords
This publication has 14 references indexed in Scilit:
- Clinical evaluation of a breathing protocol for PET/CTEuropean Radiology, 2003
- SPECT/CT hybrid imaging with 111In‐pentetreotide in assessment of neuroendocrine tumoursClinical Endocrinology, 2003
- PET/CT scanners: A hardware approach to image fusionSeminars in Nuclear Medicine, 2003
- SPECT/CT in tumor imaging: Technical aspects and clinical applicationsSeminars in Nuclear Medicine, 2003
- Benefit of anatomical-functional image fusion in the diagnostic work-up of neuroendocrine neoplasmsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Thyroid carcinomaThe Lancet, 2003
- SPET/CT image co-registration in the abdomen with a simple and cost-effective toolEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Image registration: an essential tool for nuclear medicineEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- False positive 131I whole body scans in thyroid cancer.The British Journal of Radiology, 2000
- Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first imagesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2000