Unloading of the work of breathing by proportional assist ventilation in a lung model
- 1 February 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 25 (2) , 267-272
- https://doi.org/10.1097/00003246-199702000-00012
Abstract
Objectives Proportional assist ventilation is devised to increase airway pressure in proportion to inspiratory effort. A systematic study of the performance of this new mode of ventilation has not been presented. We tested in the laboratory the capability of proportional assist ventilation to unload the work of breathing in proportion to ventilatory drive, under a variety of mechanical loads. Design During variations of "ventilatory drive" (i.e., tidal volume), unloading of the work of breathing by proportional assist ventilation was contrasted with unloading by pressure-support ventilation. Setting The respiratory laboratory of a university-affiliated teaching hospital. Subject A bellows-in-a-box lung model, powered by a sine wave air flow generator. Interventions Proportional assist and pressure-support ventilation were preset to provide comparable support at a baseline "ventilatory drive" of 0.7-L tidal volume. The set levels of proportional assist and pressure-support ventilation were subsequently applied to five tidal volumes, from 0.2 to 1.2 L. Three levels of inspiratory support and three settings of mechanical load were evaluated. Measurements and Main Results Proportional assist ventilation significantly (p < .05) reduced the work of breathing of the lung model at all but the lowest tidal volume (0.2 L). The preset proportion of ventilatory support (30%, 50%, and 70%) unloaded the work of breathing uniformly as ventilatory drive was varied at tidal volumes of >or=to0.5 L, but not always at tidal volumes of <or=to0.4 L. In contrast, pressure-support ventilation overassisted low tidal volumes and underassisted high tidal volumes (p < .05). Conclusions In a lung model, a prototype system delivering proportional assist ventilation provided uniform unloading of the work of breathing as the ventilatory drive was varied within a tidal volume range of 0.5 to 1.2 L. These findings confirm the theoretical modeling of proportional assist ventilation. This system, however, failed to properly unload low tidal volumes of 0.2 to 0.4 L. (Crit Care Med 1997; 25:267-272)Keywords
This publication has 9 references indexed in Scilit:
- Comparative evaluation of diaphragmatic activity during pressure support ventilation and intermittent mandatory ventilation in animal model.American Journal of Respiratory and Critical Care Medicine, 1994
- Patient-Ventilator Interaction with Pressure-Assisted Modalities of Ventilatory SupportSeminars in Respiratory and Critical Care Medicine, 1993
- Proportional Assist Ventilation: Results of an Initial Clinical TrialAmerican Review of Respiratory Disease, 1992
- Proportional Assist Ventilation, a New Approach to Ventilatory Support: TheoryAmerican Review of Respiratory Disease, 1992
- Comparison of Inspiratory Work of Breathing in T-Piece Breathing, PSV, and Pleural Pressure Support Ventilation (PPSV)Chest, 1991
- Impact of PEEP on lung mechanics and work of breathing in severe airflow obstructionJournal of Applied Physiology, 1988
- Respiratory Function during Pressure Support VentilationChest, 1986
- Evidence for Chronic Inflammation as a Component of the Interstitial Lung Disease Associated with Progressive Systemic SclerosisAmerican Review of Respiratory Disease, 1985
- Mechanical assistance to respiration in emphysema: Results with a patient-controlled servorespiratorThe American Journal of Medicine, 1964