Efficacy and Safety of a Polyester Leukocyte Removal Filter for Whole Blood and Red Cell Concentrate Filtration
- 1 January 1989
- journal article
- research article
- Published by Walter de Gruyter GmbH in cclm
- Vol. 27 (5) , 331-336
- https://doi.org/10.1515/cclm.1989.27.5.331
Abstract
Patients receiving multiple whole blood transfusions often experience adverse clinical symptoms caused by leukocytes. In the present study, the efficacy and safety of a polyester filter for leukocytes (Sepacell R-500) was evaluated. Donor units of whole blood and red cell concentrate stored for varying lengths of time were filtered. Emphasis was placed on humoral parameters indicative of release and/or activation reactions of granulocytes (neutral proteinase elastase, lysozyme, aggregation, chemiluminescence) and erythrocytes (lactate dehydrogenase, plasma haemoglobin). Nonspecific adsorption effects were investigated by plasma protein determinations (albumin, .alpha.2-macroglobulin). A complete blood cell count as well as values of haemoglobin and haematocrit were determined. Sepacell R-500 proved to be a highly efficient filter to the leukocyte depletion of blood. Our results of erythrocyte and granulocyte related humoral parameters provided no significant evidence of filtration mediated activation or releasing reactions of clinical consequence.This publication has 9 references indexed in Scilit:
- Receptor-mediated endocytosis of lactate dehydrogenase M4 by liver macrophages: a mechanism for elimination of enzymes from plasma. Evidence for competition by creatine kinase MM, adenylate kinase, malate, and alcohol dehydrogenase.Journal of Biological Chemistry, 1987
- Tissue injury in inflammation. Oxidants, proteinases, and cationic proteins.Journal of Clinical Investigation, 1987
- Deleterious effects of cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1985
- Effect of Different Dialyzers on Proteinases and Proteinase Inhibitors during HemodialysisAmerican Journal of Nephrology, 1985
- On the kinetics of complement activation, leucopenia and granulocyte-elastase release induced by haemodialysisScandinavian Journal of Clinical and Laboratory Investigation, 1985
- Further evaluation of a new filter for leucocyte depletion of blood.Journal of Clinical Pathology, 1984
- Evaluation of a new filter for leucocyte depletion of blood.Journal of Clinical Pathology, 1983
- LEUCOCYTE DEPLETED BLOOD: AN APPRAISAL OF AVAILABLE TECHNIQUESBritish Journal of Haematology, 1982
- Complement (C5-a)-induced granulocyte aggregation in vitro. A possible mechanism of complement-mediated leukostasis and leukopenia.Journal of Clinical Investigation, 1977