Comparison of accelerometers with oxygen consumption in older adults during exercise
- 1 January 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 31 (1) , 171-175
- https://doi.org/10.1097/00005768-199901000-00026
Abstract
Comparison of accelerometers with oxygen consumption in older adults during exercise. Med. Sci. Sports Exerc., Vol. 31, No. 1, pp. 171-175, 1999. The purpose of this study was to compare two commercially available accelerometers with indirect calorimetry in a group of older adults (x ± SD; 70.6 ± 3.7 yr; N = 86, 44 males and 42 females). The accelerometers (Caltrac and Tritrac, Hemokinetics, Madison, WI) were worn while performing three submaximal, discontinuous (5 min exercise, 2 min recovery), progressive levels of treadmill walking and bench stepping. The treadmill exercise averaged 3.4 mph, at 0.4% grade, 3.0% grade, and 5.1% grade, while the stepping work rates (24 steps·min−1) were performed on 15.2-, 20.3-, and 25.4-cm steps. Estimated energy expenditure (EE) from the two accelerometers was compared with EE as measured by indirect calorimetry. The Caltrac significantly (P P These data indicate that the magnitude of the differences between measured and estimated EE is affected by exercise mode and intensity and that caution is warranted when using the accelerometers in an attempt to quantify EE in older adults.Keywords
This publication has 12 references indexed in Scilit:
- Physical Activity, Sport, and Health: Toward the Next CenturyResearch Quarterly for Exercise and Sport, 1996
- Accuracy of five electronic pedometers for measuring distance walkedMedicine & Science in Sports & Exercise, 1996
- Validity of the Computer Science and Applications, Inc. (CCA) activity monitorMedicine & Science in Sports & Exercise, 1995
- Validity of the Physical Activity Interview and Caltrac With Preadolescent ChildrenResearch Quarterly for Exercise and Sport, 1994
- Comparison of energy expenditure in normal-weight and overweight women using the Caltrac Personal Activity Computer®International Journal of Eating Disorders, 1994
- Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditureMedicine & Science in Sports & Exercise, 1990
- The Validity of Objective Physical Activity Monitoring in Older IndividualsResearch Quarterly for Exercise and Sport, 1990
- Calorimetric Validation of the Caltrac® Accelerometer During Level WalkingPTJ: Physical Therapy & Rehabilitation Journal, 1989
- Assessment of Walking Behavior: Effect of Speed and Monitor Position on Two Objective Physical Activity MonitorsResearch Quarterly for Exercise and Sport, 1988
- Predictors of Academic and Clinical Performance in a Baccalaureate Physical Therapy ProgramPTJ: Physical Therapy & Rehabilitation Journal, 1988