Abstract
This paper extends an ejector theory which has previously been confirmed by the experiments of others. By means of the theory a new criterion of ejector performance and a new equation for ejector design are derived. Both the criterion and the equation are illustrated by a sample calculation in which a convenient computation procedure is employed. The procedure is adaptable to calculations for dissimilar fluids.

This publication has 0 references indexed in Scilit: