Twenty-Year Evaluation of Meniscal Bearing and Rotating Platform Knee Replacements
- 1 July 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 388 (388) , 41-50
- https://doi.org/10.1097/00003086-200107000-00008
Abstract
Clinical results of the initial cemented and cementless series of 373 New Jersey Low Contact Stress total knee replacements in 282 patients surviving at least 10 years were analyzed using a strict knee scoring scale. The study showed excellent, good, fair, or poor results in 68.1%, 29.8%, 2.1%, or 0% of primary posterior cruciateretaining meniscal bearing knee replacements, 46.7%, 53.3%, 0%, or 0% results in primary cemented rotating platform knee replacements, and 68.1%, 29.8%, 2.1%, or 0% results in primary cementless rotating platform knee replacements, respectively. Radiographic evaluation at minimum 10-year followup showed stable fixation of all components, no gross migration but significant osteolysis requiring bearing exchange and bone grafting in three cementless rotating platform knee replacements (1.8%) in three patients who underwent previous surgeries at an average of 10.2 years from the index surgery. Survivorship of the patients who underwent primary cementless posterior cruciate-retaining meniscal bearing knee replacements with an end point of revision for any mechanical reason was 97.4% at 10 years and 83% at 16 years; using an end point of a poor clinical knee score the survivorship was 98.9% at 10 years and at 16 years. Survivorship of the patients who underwent primary cemented rotating platform knee replacements with end points of revision for any mechanical reason or a poor clinical knee score was 97.7% at 10 years and at 20 years. Survivorship of the patients who underwent cementless rotating platform knee replacements with end points of revision for any mechanical reason or a poor clinical knee score was 98.3% at 10 years and at 18 years.Keywords
This publication has 13 references indexed in Scilit:
- Mobile-Bearing Knee ReplacementJournal of Bone and Joint Surgery, 2000
- Cemented Rotating-Platform Total Knee ReplacementJournal of Bone and Joint Surgery, 2000
- The TRAC PS mobile-bearing prosthesis: Design rationale and in vivo 3-dimensional laxityThe Journal of Arthroplasty, 2000
- Results and complications of the low contact stress knee prosthesisThe Journal of Arthroplasty, 1999
- Medium Term Results of a Mobile Bearing Total Knee ReplacementClinical Orthopaedics and Related Research, 1999
- Survivorship Analysis of Cementless Meniscal Bearing Total Knee ArthroplastyPublished by Wolters Kluwer Health ,1997
- Theory and Practice of Meniscal Knee Replacement: Designing against WearProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996
- Polyethylene wear in meniscal knee replacement. A one to nine-year retrieval analysis of the Oxford kneeThe Journal of Bone and Joint Surgery. British volume, 1992
- Failure of the polyethylene bearing surface of a total knee replacement within four years. A case report.Journal of Bone and Joint Surgery, 1988
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958