Recording characteristics of monopolar emg electrodes
- 1 February 1991
- journal article
- research article
- Published by Wiley in Muscle & Nerve
- Vol. 14 (2) , 108-112
- https://doi.org/10.1002/mus.880140204
Abstract
Motor unit action potentials (MUAPs) and the electromyographic (EMG) interference pattern (IP) were recorded from the biceps muscle of 5 normal subjects using both a concentric needle (CN) and a disposable monopolar needle (MN) electrode. The MUAPs recorded by the MN electrode had higher amplitude and area and were more frequently complex than those recorded with the CN electrode. The MUAP duration and area: amplitude ratio were similar for both electrodes. Although the MN electrode had a larger recording surface, its dimensions (maximum diameter and length of the cone shaped tip) were similar to those of the CN electrode (minor and major axes of the elliptical recording tip). Based on these observations, we infer that the MN electrode may be more selective than the CN electrode, ie, the AP amplitude recorded by the MN electrode decreases faster than the AP amplitude recorded by a CN electrode when the distance of the muscle fiber from the recording electrode increases. Photomicrographs of the MN electrode after use demonstrated no evidence that the insulating material had peeled off. There was also no evidence that MUAP measurement values changed during the recordings as would be expected if the recording surface changed due to peeling of the insulating material.Keywords
This publication has 8 references indexed in Scilit:
- Evaluation of an automatic method of measuring features of motor unit action potentialsMuscle & Nerve, 1989
- Properties of motor unit action potentials recorded with concentric and monopolar needle electrodes: ADEMG analysisMuscle & Nerve, 1988
- Analysis of amplitude and area of concentric needle EMG motor unit action potentialsElectroencephalography and Clinical Neurophysiology, 1988
- Simulation of concentric needle EMG motor unit action potentialsMuscle & Nerve, 1988
- Automatic analysis of the EMG interference patternElectroencephalography and Clinical Neurophysiology, 1983
- Single fibre electromyographyTrends in Neurosciences, 1979
- How the size of the needle electrode leading-off surface influences the shape of the single muscle fibre action potential in electromyographyComputer Programs in Biomedicine, 1973
- Dependence of Scalar Potential Measurements on Electrode GeometryReview of Scientific Instruments, 1965