Comparative assessments of objective peak-detection algorithms. II. Studies in men
- 1 January 1988
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Endocrinology and Metabolism
- Vol. 254 (1) , E113-E119
- https://doi.org/10.1152/ajpendo.1988.254.1.e113
Abstract
The performances of eight currently available computerized pulse-detection algorithms were compared on signal-free noise and physiological luteinizing hormone (LH) time series. Signal-free noise was made to vary from 4 to 36% for Gaussian and empirical distributions. Physiological LH data were obtained by immunoassay of blood samples withdrawn every 5 min for 24 h in 8 healthy men, so that the data sets could be emended to simulate varying sampling intensities. Whenever possible, programs were tested at a presumptive 1% false-positive rate. In relation to signal-free noise, the Santen and Bardin program and its modification manifested elevated false-positive rates when the intraseries coefficients of variation increased. The Regional Dual-Threshold program yielded a 1% false-positive rate except on simulated series with high variance. The Cluster and Detect programs both approximated a 1% false-positive rate and the Ultra program approximated a 2.3% false-positive rate throughout the entire range of variance tested. In regard to physiological LH data, all algorithms disclosed a significant impact of sampling intensity on estimates of LH pulse frequency. Sampling-intensity dependent estimates of LH peak frequency by three of the eight programs (Ultra, Cluster, and Detect) were statistically indistinguishable from each other but distinct from the five other programs tested. Furthermore, when judged in relation to their ability to identify individual peaks, the three congruent programs were minimally distinguishable (McNemar's test). Rather, these programs identified the same particular peaks (as defined by concordance of peak maxima) at least 72% of the time.This publication has 8 references indexed in Scilit:
- Appraising Endocrine Pulse Signals at Low Circulating Hormone Concentrations: Use of Regional Coefficients of Variation in the Experimental Series To Analyze Pulsatile Luteinizing Hormone ReleasePediatric Research, 1986
- Detection and characterization of peaks and estimation of instantaneous secretory rate for episodic pulsatile hormone secretionComputers and Biomedical Research, 1986
- Cluster analysis: a simple, versatile, and robust algorithm for endocrine pulse detectionAmerican Journal of Physiology-Endocrinology and Metabolism, 1986
- Performance of LH pulse-detection algorithms at rapid rates of venous sampling in humansAmerican Journal of Physiology-Endocrinology and Metabolism, 1984
- Intensified Rates of Venous Sampling Unmask the Presence of Spontaneous, High-Frequency Pulsations of Luteinizing Hormone in Man*Journal of Clinical Endocrinology & Metabolism, 1984
- Mapping episodic fluctuations in plasma LH in orchidectomized ratsAmerican Journal of Physiology-Endocrinology and Metabolism, 1984
- Cycle Detection: A Technique for Estimating the Frequency and Amplitude of Episodic Fluctuations inBlood Hormone and Substrate Concentrations*Endocrinology, 1983
- Algorithms for the study of episodic hormone secretionAmerican Journal of Physiology-Endocrinology and Metabolism, 1982