Application of autoregressive spectral analysis for ultrasound attenuation estimation: interest in highly attenuating medium
- 1 January 1995
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 42 (1) , 99-110
- https://doi.org/10.1109/58.368307
Abstract
The authors deal with the application of parametric spectral analysis for attenuation estimation on the reflected ultrasound signal of biological tissues. A second-order autoregressive (AR2) model, whose parameters are estimated with the Burg algorithm, is used to estimate the center frequency on echo signals and its evolution versus depth. Data simulation of independent A-lines backscattered by a homogeneous medium of scatterers are generated by a computer model with attenuation values ranging from 1 to 5 dB/cmMHz, an ultrasonic frequency of 5 MHz and different pulse durations. The performance of the estimator is evaluated for time windows ranging from 5 to 0.3 /spl mu/s. The comparison is made with the classical short time Fourier analysis using a fast Fourier transform (FFT). It is found that the AR2 model provides a better estimation of attenuation than the Fourier technique: the relative error of attenuation is below 5% for windows between 0.6 to 2.5 /spl mu/s, while the one obtained with the Fourier technique lies between 3 and 16% for the same window sizes. However, the variance of attenuation estimate is the same with the two techniques. These results offer promises for determining attenuation in highly attenuating medium (material or biological tissue) either because of their structure or because high frequencies are used.<>Keywords
This publication has 26 references indexed in Scilit:
- Order selection in Doppler blood flow signal spectral analysis using autoregressive modellingMedical & Biological Engineering & Computing, 1989
- Ultrasound attenuation estimation in soft tissue using the entropy difference of pulsed echoes between two adjacent envelope segmentsUltrasonic Imaging, 1988
- Diffraction correction for focused transducers in attenuation measurements ?Ultrasonic Imaging, 1987
- Reduced-order autoregressive modeling for center-frequency estimationUltrasonic Imaging, 1985
- Bounds on estimating the acoustic attenuation of small tissue regions from reflected ultrasoundProceedings of the IEEE, 1985
- Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation TechniquePublished by Institute of Electrical and Electronics Engineers (IEEE) ,1985
- The Measurement of Broadband Ultrasonic Attenuation in Cancellous BoneEngineering in Medicine, 1984
- Analysis of Blood Velocity Waveforms by Phase Shift Averaging and Autoregressive Spectral EstimationJournal of Biomechanical Engineering, 1983
- Spectrum analysis—A modern perspectiveProceedings of the IEEE, 1981
- Estimating the Acoustic Attenuation Coefficient Slope for Liver from Reflected Ultrasound SignalsIEEE Transactions on Sonics and Ultrasonics, 1979