Closed-Loop Artificial Pancreas Using Subcutaneous Glucose Sensing and Insulin Delivery and a Model Predictive Control Algorithm: The Virginia Experience
Open Access
- 1 September 2009
- journal article
- abstracts
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 3 (5) , 1031-1038
- https://doi.org/10.1177/193229680900300506
Abstract
Recent progress in the development of clinically accurate continuous glucose monitors (CGMs), automated continuous insulin infusion pumps, and control algorithms for calculating insulin doses from CGM data have enabled the development of prototypes of subcutaneous closed-loop systems for controlling blood glucose (BG) levels in type 1 diabetes. The use of a new personalized model predictive control (MPC) algorithm to determine insulin doses to achieve and maintain BG levels between 70 and 140 mg/dl overnight and to control postprandial BG levels is presented. Eight adults with type 1 diabetes were studied twice, once using their personal open-loop systems to control BG overnight and for 4 h following a standardized meal and once using a closed-loop system that utilizes the MPC algorithm to control BG overnight and for 4 h following a standardized meal. Average BG levels, percentage of time within BG target of 70–140 mg/dl, number of hypoglycemia episodes, and postprandial BG excursions during both study periods were compared. With closed-loop control, once BG levels achieved the target range (70–140 mg/dl), they remained within that range throughout the night in seven of the eight subjects. One subject developed a BG level of 65 mg/dl, which was signaled by the CGM trend analysis, and the MPC algorithm directed the discontinuance of the insulin infusion. The number of overnight hypoglycemic events was significantly reduced (p = .011) with closed-loop control. Postprandial BG excursions were similar during closed-loop and open-loop control Model predictive closed-loop control of BG levels can be achieved overnight and following a standardized breakfast meal. This “artificial pancreas” controls BG levels as effectively as patient-directed open-loop control following a morning meal but is significantly superior to open-loop control in preventing overnight hypoglycemia.Keywords
This publication has 14 references indexed in Scilit:
- Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump SuspensionDiabetes Technology & Therapeutics, 2009
- Fully Automated Closed-Loop Insulin Delivery Versus Semiautomated Hybrid Control in Pediatric Patients With Type 1 Diabetes Using an Artificial PancreasDiabetes Care, 2008
- Detection of a Meal Using Continuous Glucose MonitoringDiabetes Care, 2008
- Linear Quadratic Gaussian-Based Closed-Loop Control of Type 1 DiabetesJournal of Diabetes Science and Technology, 2007
- Model Predictive Control of Type 1 Diabetes: An in Silico TrialJournal of Diabetes Science and Technology, 2007
- Meal Simulation Model of the Glucose-Insulin SystemIEEE Transactions on Biomedical Engineering, 2007
- The artificial pancreas: how close are we to closing the loop?2007
- Feasibility of Automating Insulin Delivery for the Treatment of Type 1 DiabetesDiabetes, 2006
- Model-based blood glucose control for type 1 diabetes via parametric programmingIEEE Transactions on Biomedical Engineering, 2006
- Closed-loop and Open-loop Devices for Blood Glucose Control in Normal and Diabetic SubjectsDiabetes, 1978