Soft X-ray tomography in the JIPP T-II stellarator
- 1 August 1982
- journal article
- letter
- Published by IOP Publishing in Nuclear Fusion
- Vol. 22 (8) , 1082-1085
- https://doi.org/10.1088/0029-5515/22/8/008
Abstract
Tomography based on poloidal harmonic expansion is modified to be applied to an elliptical source in order to investigate the internal mode structures due to tearing modes in the ℓ = 2 stellarator configuration. This method was applied to the soft X-ray signals of the JIPP T-II stellarator and the image of the m = 2 magnetic island of the plasma was obtained.Keywords
This publication has 12 references indexed in Scilit:
- Two-dimensional spatial distribution of volume emission from line integral dataReview of Scientific Instruments, 1981
- Soft X-Ray Tomography of the m=2 Magnetic Island Structure in the JIPP T-II TokamakJapanese Journal of Applied Physics, 1981
- Stabilization of the (2, 1) tearing mode and of the current disruption in the W VII–A stellaratorNuclear Fusion, 1980
- Methods for Reconstructing Spatial Distributions of Radiation from PlasmasIEEE Transactions on Plasma Science, 1980
- Techniques for the Reconstruction of Two-Dimensional Images from ProjectionsIEEE Transactions on Plasma Science, 1979
- Computerized tomography: taking sectional x raysPhysics Today, 1977
- Construction, Restoration, and Enhancement of 2 and 3-Dimensional ImagesIEEE Transactions on Nuclear Science, 1977
- Hybrid stellarator fields with several values of ℓNuclear Fusion, 1973
- Representation of a Function by Its Line Integrals, with Some Radiological Applications. IIJournal of Applied Physics, 1964