Plasma lipid profiling by liquid chromatography with chloride‐attachment mass spectrometry
- 1 March 1991
- Vol. 26 (3) , 240-246
- https://doi.org/10.1007/bf02543979
Abstract
A sensitive high-performance liquid chromatographic assay was developed using chloride attachment negative chemical ionization mass spectrometry for detection of glyceryl esters and ceramides, and positive chemical ionization mass spectrometry for detection of free cholesterol and cholesteryl esters in minimal quantities of plasma. The novel technique was validated by high temperature gas-liquid chromatography with flame ionization detection. Sample preparation was achieved by phospholipase C digestion of whole plasma, total lipid extraction and derivatization of any free carboxyl and hydroxyl groups by trimethyl- ortert-butyldimethyl-chlorosilane. The lipids were separated by reverse phase HPLC with 20–90% propionitrile in acetonitrile containing 1% dichloromethane, which served as the reagent and the source of chloride. Negative chemical ionization with chloride attachment is estimated to provide about 100 times higher response for the triacylglycerols and the trimethylsilyl ortert-butyldimethylsilyl ethers of diacylglycerols, and about 500 times higher response for the trimethylsilyl ortert-butyldimethylsilyl ethers of ceramides than positive chemical ionization mass spectrometry. Determination of the full negative chemical ionization mass spectra showed that each glycerolipid and ceramide species yielded a single ionic species corresponding to the chloride-attachment product of the parent ion. The cholesteryl esters and ethers failed to attach chloride and remained undetected by negative chemical ionization. However, the cholesteryl esters and ethers gave a high response for the steroid nucleus in positive chemical ionization mass spectrometry. Chloride attachment negative chemical ionization mass spectrometry is suitable for the unequivocal identification of plasma glycerolipids and ceramides in high-performance liquid chromatography and for the quantitation of molecular species in any unresolved peaks following appropriate calibration of the instrument response.Keywords
This publication has 25 references indexed in Scilit:
- Quantitative analysis of triglycerides by high-performance liquid chromatography using non-linear gradient elution and flame ionization detectionJournal of Chromatography A, 1988
- Capillary gas chromatography/mass spectrometry of cholesteryl esters with negative ammonia chemical ionizationJournal of Mass Spectrometry, 1987
- Determination of eicosanoids, phospholipids and related compounds by thermospray liquid chromatography-mass spectometryJournal of Chromatography A, 1987
- Liquid chromatography/mass spectrometryAnalytical Chemistry, 1986
- Deacylation of endogenously deuterated rat liver microsomal phospholipids by endogenous phospholipasesCanadian Journal of Biochemistry and Cell Biology, 1985
- Liquid chromatography—chloride-attachment negative chemical ionization mass spectrometryJournal of Chromatography A, 1985
- Resolution of alkenylacylglycerol moieties of natural glycerophospholipids by gas–liquid chromatography on polar capillary columnsCanadian Journal of Biochemistry and Cell Biology, 1984
- Resolution and quantitation of diacylglycerol moieties of natural glycerophospholipids by reversed-phase liquid chromatography with direct liquid inlet mass spectrometryCanadian Journal of Biochemistry and Cell Biology, 1984
- Analysis of triacylglycerols by reversed-phase high pressure liquid chromatography with direct liquid inlet mass spectrometryCanadian Journal of Biochemistry and Cell Biology, 1983
- Negative chemical ionization mass spectrometryAnalytical Chemistry, 1981