In vivo intracranial pressure dynamics in patients with hydrocephalus treated by shunt placement
- 1 June 2000
- journal article
- clinical trial
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 92 (6) , 927-932
- https://doi.org/10.3171/jns.2000.92.6.0927
Abstract
With the commercial availability of a variety of shunt systems, there is considerable controversy over the choice of the most appropriate shunt valve for each individual with hydrocephalus. Although the performance characteristics of all shunt systems are well documented in the laboratory setting, there is little description of the in vivo dynamics of intracranial pressure (ICP) after implantation of commonly used shunt systems in humans. The authors coupled telemonitoring devices to several different shunt systems to measure the performance characteristics of these valve systems with respect to intraventricular pressure (IVP) at increments of head elevation. Twenty-five patients with different shunt systems and three control patients without shunts were studied for IVP at 0 degrees, 15 degrees, 30 degrees, 45 degrees, 60 degrees, 75 degrees, and 90 degrees of head elevation, and the resultant curves were analyzed for the best-fit regression coefficient. For purposes of analysis the authors grouped shunt valve systems by design characteristics into three groups: differential-pressure valves (r = -0.321 +/- 0.061; 11 patients), nonsiphoning systems (r = -0.158 +/- 0.027; 10 patients), and flow-regulated valves (r = -0.16 +/- 0.056; four patients); there were three control patients without shunts (r = -0.112 +/- 0.037). The authors found that differential-pressure valves always caused ICP to drop to 0 by 30 degrees of head elevation, whereas all other valve systems caused a more gradual drop in ICP, more consistent with pressures observed in the control patients without shunts. Not surprisingly, the differential-pressure valve group was found to have a significant difference in mean regression coefficient when compared with those in whom nonsiphoning shunts (p < 0.023) or no shunts were placed (p < 0.049). These data provide a basis for evaluating shunt valve performance and for predicting valve appropriateness in patients in whom characteristics such as pressure and flow dynamics are weighed in the choice of a specific valve for implantation.Keywords
This publication has 30 references indexed in Scilit:
- Risks in using siphon-reducing devices in adult patients with normal-pressure hydrocephalus: bench test investigations with Delta valvesJournal of Neurosurgery, 1996
- Current Treatment of Normal-pressure HydrocephalusNeurosurgery, 1995
- Negative-pressure hydrocephalusJournal of Neurosurgery, 1995
- The treatment of hydrocephalus: a brief guide to shunt selectionSurgical Neurology, 1995
- Effects of head elevation on intracranial hemodynamics in patients with ventriculoperitoneal shuntsJournal of Neurosurgery, 1994
- Experience with Telemetric Pressure Measurements in Shunt SystemsPediatric Neurosurgery, 1994
- Testing the Hydrocephalus Shunt Valve: Long-Term Bench Test Results of Various New and Explanted Valves. The Need for a Model for Testing Valves Under Physiological ConditionsEuropean Journal of Pediatric Surgery, 1991
- Optimum position for an anti-siphon device in a cerebrospinal fluid shunt systemNeurosurgery, 1991
- Hydrocephalus: Overdrainage by ventricular shunts. A review and recommendationsSurgical Neurology, 1991
- Intellectual Development and Brain Size in 13 Shunted Hydrocephalic ChildrenNeuropediatrics, 1978