Factors that influence lymphocyte yields in lymphocytapheresis
- 6 May 1985
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 25 (3) , 242-245
- https://doi.org/10.1046/j.1537-2995.1985.25385219906.x
Abstract
The recent use of lymphocytapheresis to treat immune‐mediated diseases such as rheumatoid arthritis prompted a study of factors that influence the cell composition of lymphocytapheresis concentrates. Following single cytapheresis procedures, using protocols recommended by manufacturers, lymphocyte yields were significantly higher with the model 2997 (IBM) and CS‐3000 (Fenwal) cell separators as compared to the model 30 (Haemonetics) separator (9.8 ± 1.1 and 7.1 ± 1.2 × 109 lymphocytes, respectively, versus 4.6 ± 1.1 × 109; p < 0.01). The lymphocyte concentrate obtained with the CS‐3000 separator contained the smallest number of monocytes (0.6 ± 0.4 × 109 versus 1.4 ± 1.6 and 1 ± 0.3 × 109 for the model 2997 and 30 cell separators, respectively). Platelet contamination of the lymphocyte concentrate was highest with the CS‐3000 (6.5 ± 2.4 × 1011, and erythrocyte contamination was highest when the model 30 was used (21 ± 3.0%). Studies using the model 2997 indicated that lymphocyte yields were significantly influenced by donor pre‐apheresis absolute lymphocyte counts, and for this cell separator by specific operating variables, such as channel centrifugation speed and positioning of the red cell interface during lymphocyte collection. Maximal yields were obtained when the channel centrifugation speed was 800 to 1000 rpm (equivalent to 100–150 × g) and the red cell interface was adjusted to yield a cell concentrate with a hematocrit less than 4 percent. These results suggest that it will be necessary to standardize lymphocytapheresis collection protocols in future studies to assess the role of lymphocytapheresis in the management of immune‐mediated diseases such as rheumatoid arthritis.This publication has 9 references indexed in Scilit:
- Plateletpheresis Experience with the Haemonetics Blood Processor 30, the IBM Blood Processor 2997, and the Fenwal CS‐3000 Blood Processor1,2Vox Sanguinis, 1981
- Lymphocyte depletion and immunosuppression with repeated leukapheresis by continuous flow centrifugationBlood, 1981
- Lymphapheresis in rheumatoid arthritisArthritis & Rheumatism, 1981
- The effect of thoracic duct drainage on lymphocyte dynamics and clinical symptoms in patients with rheumatoid arthritisArthritis & Rheumatism, 1979
- Lymphocyte depletion by continuous flow cell centrifugation in rheumatoid arthritisArthritis & Rheumatism, 1979
- Plasmapheresis and lymphoplasmapheresis in the management of rheumatoid arthritisArthritis & Rheumatism, 1979
- Leucapheresis in severe rheumatoid arthritis.Annals of the Rheumatic Diseases, 1979
- Use of Hydroxyethyl Starch To Improve Granulocyte Collection in the Latham Blood ProcessorTransfusion, 1975
- Cytochemical Identification of Monocytes and GranulocytesAmerican Journal of Clinical Pathology, 1971