Low measured auto-positive end-expiratory pressure during mechanical ventilation of patients with severe asthma
- 1 March 1996
- journal article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 24 (3) , 541-546
- https://doi.org/10.1097/00003246-199603000-00028
Abstract
To describe the occurrence of low measured auto-end-expiratory pressure (auto-PEEP) during mechanical ventilation of patients severe asthma. Observational clinical study. Medical intensive care unit of a university-affiliated county hospital. Four mechanically ventilated patients with severe asthma who had low measured auto-PEEP despite marked increase in both peak and plateau airway pressures. None. Peak pressure, plateau pressure, and auto-PEEP were measured at an early time point, when airflow obstruction was most severe, and again at a later time after clinical improvement. Auto-PEEP was measured by the method of end-expiratory airway occlusion. From the early to the late point, there was a marked decrease in peak pressure (76 +/- 7 to 53 +/- 6 cm H2O; p<.001) and in plateau pressure (28 +/- 2 to 18 +/- 3 cm H2O; p<.001), but only minimal change in auto-PEEP (5 +/- 3 to 4 +/- 3 cm H2O). The difference between plateau pressure and auto-PEEP decreased between the early and late time points (23 +/- 1 to 14 +/- 1 cm H2O; p<.01), even though tidal volume was larger at the late time point. In three patients, low auto-PEEP and a large difference between plateau pressure and auto-PEEP was only seen after expiratory time was prolonged. In these three patients, prolongation of expiratory time resulted in a large decrease in measured auto-PEEP (14 +/- 4 to 5 +/- 4 cm H2O), but a much smaller change in plateau pressure (31 +/- 3 to 29 +/- 3 cm H2O). We conclude that measured auto-PEEP may underestimate end-expiratory alveolar pressure in severe asthma, and that marked pulmonary hyperinflation may be present despite low measured auto-PEEP, especially at low respiratory rates. This phenomenon may be due to widespread airway closure that prevents accurate assessment of alveolar pressure at end-expiration.Keywords
This publication has 16 references indexed in Scilit:
- Pathology of asthmaJournal of Allergy and Clinical Immunology, 1993
- Use of a Measurement of Pulmonary Hyperinflation to Control the Level of Mechanical Ventilation in Patients with Acute Severe AsthmaAmerican Review of Respiratory Disease, 1992
- Risk Factors for Morbidity in Mechanically Ventilated Patients with Acute Severe AsthmaAmerican Review of Respiratory Disease, 1992
- The Mechanics of Airway Narrowing in AsthmaAmerican Review of Respiratory Disease, 1989
- Respiratory Mechanics during the First Day of Mechanical Ventilation in Patients with Pulmonary Edema and Chronic Airway ObstructionAmerican Review of Respiratory Disease, 1988
- The Effects of Ventilatory Pattern on Hyperinflation, Airway Pressures, and Circulation in Mechanical Ventilation of Patients with Severe Air-Flow ObstructionAmerican Review of Respiratory Disease, 1987
- Respiratory System Mechanics in Ventilated Patients: Techniques and IndicationsMayo Clinic Proceedings, 1987
- The stability of peripheral airwaysRespiration Physiology, 1970
- Lung volumes in exacerbations of asthmaThe American Journal of Medicine, 1966
- Ventilatory Function in Bronchial AsthmaThorax, 1952