High‐resolution computer simulation of the dynamics of isoelectric focusing of proteins
- 19 January 2004
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 25 (2) , 324-337
- https://doi.org/10.1002/elps.200305749
Abstract
A dynamic electrophoresis simulator that accepts 150 components and voltage gradients employed in the laboratory was used to provide a detailed description of the focusing process of proteins under conditions that were hitherto inaccessible. High‐resolution focusing data of four hemoglobin variants in a convection‐free medium are presented for pH 3–10 and pH 5–8 gradients formed with 20 and 40 carrier ampholytes/pH unit, respectively. With 300 V/cm, focusing is shown to occur within 5–10 min, whereas at 600 V/cm separation is predicted to be complete between 2.5 and 5 min. The time interval required for focusing of proteins is demonstrated to be dependent on the input protein charge data and, however less, on the properties of the carrier ampholytes. The simulation data reveal that the number of transient protein boundaries migrating from the two ends of the column towards the focusing positions is equal to the number of sample components. Each protein is being focused via the well‐known double‐peak approach to equilibrium, a process that is also characteristic for focusing of the carrier ampholytes. The predicted focusing dynamics for the hemoglobin variants in pH 3–10 and pH 5–8 gradients are shown to qualitatively agree well with experimental data obtained by whole‐column optical imaging.Keywords
This publication has 41 references indexed in Scilit:
- Application of capillary isoelectric focusing with absorption imaging detection to the quantitative determination of human hemoglobin variantsElectrophoresis, 1995
- Computer simulation of electrophoretic transport. I. General procedure and an application to isoelectric focusing of proteins using carrier ampholytes.SEIBUTSU BUTSURI KAGAKU, 1994
- Universal detection for capillary isoelectric focusing without mobilization using concentration gradient imaging systemAnalytical Chemistry, 1992
- Role of charge suppression and ionic strength in free zone electrophoresis of proteinsAnalytical Chemistry, 1991
- Experimental and theoretical description of the isotachophoretic behavior of serum albuminElectrophoresis, 1990
- Experimental and theoretical dynamics of isoelectric focusing III. Transient multi-peak approach to equilibrium of proteins in simple buffersJournal of Chromatography A, 1989
- HISTORICAL AND THEORETICAL ASPECTS OF ISOELECTRIC FOCUSING*Annals of the New York Academy of Sciences, 1973
- ANALYTICAL SCANNING ISOELECTROFOCUSING*Annals of the New York Academy of Sciences, 1973
- Free zone electrophoresisChromatographic Reviews, 1967
- Studies in the Physical Chemistry of the Proteins. XIV. The Amphoteric Properties of Hemoglobin*Journal of the American Chemical Society, 1937