Sensitivity and Specificity of the Head-Shaking Test for Detecting Vestibular System Abnormalities
- 1 July 1990
- journal article
- research article
- Published by SAGE Publications in Annals of Otology, Rhinology & Laryngology
- Vol. 99 (7) , 539-542
- https://doi.org/10.1177/000348949009900708
Abstract
The head-shaking nystagmus (HSN) test has been reported to be a sensitive screening test for the presence of peripheral and central vestibular system disease. Previous investigations have utilized few subjects who were drawn from well-defined patient populations. The purpose of the present investigation was twofold: First, to determine the prevalence of HSN in a large unselected population of dizzy patients seen in an otology and neurotology practice, and second, to determine the sensitivity and specificity of this evaluation in the detection of vestibular system abnormalities as reflected by results of electronystagmography and rotary chair testing. The results of the investigation have suggested that the HSN test has a 27 % sensitivity and an 85 % specificity. The HSN test yields an acceptable number of false positives (15%) and an unacceptably large number of false negatives (73%).Keywords
This publication has 4 references indexed in Scilit:
- Two Types of Head-Shaking Tests in Vestibular ExaminationActa Oto-Laryngologica, 1988
- Head-shaking nystagmus in patients with unilateral peripheral vestibular lesionsAmerican Journal of Otolaryngology, 1987
- Clinical Significance of Biphasic Head-Shaking NystagmusAuris Nasus Larynx, 1986
- Der biphasisch auftretende KopfschüttelnystagmusEuropean Archives of Oto-Rhino-Laryngology, 1975