Fracture of the Radial Head With Associated Elbow Dislocation: Results of Treatment Using a Floating Radial Head Prosthesis
- 1 March 2000
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 14 (3) , 171-177
- https://doi.org/10.1097/00005131-200003000-00004
Abstract
To assess elbow function, complications, and problems of radial head fractures associated with elbow dislocation receiving surgical treatment with a floating prosthesis. Prospective clinical study. University Hospital, Orthopaedic Department, Sart Tilman, Liège, Belgium. Eleven consecutive adult patients were treated with a floating prosthesis for acute radial head fractures associated with elbow dislocation from January 1994 to September 1996. The floating radial head prosthesis (Tornier SA, Saint-Ismier, France) was used in all our patients. The implant is in two parts: a radial head made of high-density polyethylene enclosed in a cobalt-chrome cup, which articulates in a semi-constrained manner with the spherical end of a cemented intramedullary stem. The implants were inserted within the first week following the injury (range 2 to 7 days). Three cases also required internal fixation of the coronoid process of the ulna; in one case plate fixation of an olecranon fracture was also performed. Patients were assessed by physical examination, a functional rating index (Morrey et al.), and radiographs. The parameters evaluated were motion, stability, pain, and grip strength. Potential complications such as infection, prosthetic failure, or dislocation were investigated. The minimum follow-up time was two years (mean 32 months, range 24 to 56 months). Four patients were considered to have excellent results, four patients were considered to have good results, two patients had fair results, and one patient had a poor result. There were no cases of infection, prosthetic failure, or dislocation. No patient required prosthetic revision. The basic principle of maintaining anatomic and physiologic relationships applies when deciding on treatment for radial head fractures with associated elbow dislocation. The loss of lateral osseous support will render the elbow grossly unstable. We believe that a floating prosthesis may be indicated in Mason Type III radial head fractures associated with elbow dislocation, especially in the presence of associated destabilizing fractures. Well-controlled comparative randomized studies will be needed to delineate the optimal treatment for a given situation.Keywords
This publication has 26 references indexed in Scilit:
- Optimal Position for Plate Fixation of Complex Fractures of the Proximal Radius: A Cadaver StudyJournal of Orthopaedic Trauma, 1998
- Acute Elbow Dislocation: Evaluation and ManagementJournal of the American Academy of Orthopaedic Surgeons, 1998
- Fractures of the Radial Head Treated by Internal Fixation: Late Results in 26 CasesJournal of Orthopaedic Trauma, 1995
- Radial Head Fractures and Their Effect on the Distal Radioulnar JointPublished by Wolters Kluwer Health ,1992
- Dislocations of the Elbow and Intraarticular FracturesClinical Orthopaedics and Related Research, 1989
- Silicone Rubber Replacement of the Severely Fractured Radial HeadClinical Orthopaedics and Related Research, 1986
- Late Results in Fractures of the Radial Head Treated by ExcisionClinical Orthopaedics and Related Research, 1983
- Ulnar variance—The effect of wrist positioning and roentgen filming techniqueThe Journal of Hand Surgery, 1982
- Some observations on fractures of the head of the radius with a review of one hundred casesBritish Journal of Surgery, 1954
- USE OF ACRYLIC PROSTHESIS IN THE TREATMENT OF FRACTURE OF THE HEAD OF THE RADIUSThe Journal of Bone and Joint Surgery. British volume, 1953