Factors influencing indoor air quality in Hong Kong: Measurements in offices and shops
- 1 September 1991
- journal article
- research article
- Published by Taylor & Francis in Environmental Technology
- Vol. 12 (9) , 737-745
- https://doi.org/10.1080/09593339109385065
Abstract
Comparisons of levels of respirable suspended particulates, carbon monoxide, carbon dioxide, nitrogen dioxide, volatile organic compounds and nicotine have been made between indoor and outdoor air in 35 street‐level shops and 35 offices in Hong Kong. Additionally, counts of bacteria and fungi were made indoors. In shops, the study showed that the air quality was principally determined by outdoor air, with highly significant correlations between indoor and outdoor levels of RSP, CO and NO2. The levels of these substances were significantly lower in offices. Measurement of analytes related to tobacco smoking showed extremely low levels of environmental tobacco smoke in both shops and offices, but the overall numbers of smokers in such establishments was small. For offices, occupier complaints regarding drowsiness, headache and symptoms of eye, nose and respiratory tract irritation were positively associated with CO2 levels. NO2, CO, toluene and benzene levels did not show any relationship to occupier comfort or sick‐building syndrome complaints.Keywords
This publication has 10 references indexed in Scilit:
- The origins and properties of environmental tobacco smokeEnvironment International, 1990
- Measurements of environmental tobacco smoke in an air‐conditioned office buildingEnvironmental Technology Letters, 1989
- Air quality in passenger cabins of DC‐9 and MD‐80 aircraftEnvironmental Technology Letters, 1989
- INDOOR AIR POLLUTION IN DEVELOPING COUNTRIES AND ACUTE RESPIRATORY INFECTION IN CHILDRENThe Lancet, 1989
- Estimation of Effect of Environmental Tobacco Smoke on Air Quality within Passenger Cabins of Commercial AircraftEnvironmental Science & Technology, 1987
- Estimation of personal exposure to ambient nicotine in daily environmentInternationales Archiv für Arbeitsmedizin, 1987
- The TEAM Study: Personal exposures to toxic substances in air, drinking water, and breath of 400 residents of New Jersey, North Carolina, and North DakotaEnvironmental Research, 1987
- The Status of Indoor Air PollutionEnvironmental Health Perspectives, 1985
- Possible health effects of energy conservation: Impairment of indoor air quality due to reduction of ventilation rateEnvironment International, 1984