The effect of applied sensor contact force on pulse transit time
- 26 May 2006
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 27 (8) , 675-684
- https://doi.org/10.1088/0967-3334/27/8/002
Abstract
Pulse transit time (PTT) is usually determined as the time interval between the peak of the electrocardiogram (ECG) R wave and a characteristic point of the peripheral pulse measured by photoplethysmography. However, it was found that the photoplethysmogram (PPG) is affected by the contact force between the photoplethysmographic sensor and the measurement site, i.e. finger. Therefore, we hypothesized that the PTT may be altered by the applied sensor contact force. An ECG and PPG were recorded simultaneously from 30 healthy subjects using 12 magnitudes of contact force (0.1 N-1.8 N). Three characteristic points of the PPG were selected to determine the PTT, including the points near the foot (PTT1), on the systole phase (PTT2) and near the peak (PTT3). Both PTT1 and PTT2 increased significantly (p = 0.014 for PTT1 and p = 0.038 for PTT2) with the sensor contact force until the transmural force reached -0.1 N. With further increase in the contact force, they kept at an almost constant level. Such a changing trend was not found in PTT3. The results of this study suggest that the applied sensor contact force should be carefully controlled in PTT measurement to avoid diminishing its value as a diagnostic tool.Keywords
This publication has 35 references indexed in Scilit:
- Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toesIEE Proceedings - Science, Measurement and Technology, 2000
- Aortic Pulse Wave Velocity as a Marker of Cardiovascular Risk in Hypertensive PatientsHypertension, 1999
- Determination of Appropriate Recording Force for Non-Invasive Measurement of Arterial Pressure PulsesClinical Science, 1997
- Determination of pulse wave velocities with computerized algorithmsAmerican Heart Journal, 1991
- Calculation of pulse-wave velocity using cross correlation—Effects of reflexes in the arterial treeUltrasound in Medicine & Biology, 1991
- Oscillometric Determination of Diastolic, Mean and Systolic Blood Pressure—A Numerical ModelJournal of Biomechanical Engineering, 1986
- Relationship between pulse-wave velocity and arterial elasticityMedical & Biological Engineering & Computing, 1986
- On a non-invasive evaluation of pulse wave velocity in human peripheral arteriesClinical Physics and Physiological Measurement, 1984
- The relationship between arterial pulse-wave velocity and pulse frequency at different pressuresJournal of Medical Engineering & Technology, 1984
- The Covariation of Blood Pressure and Pulse Transit Time in Hypertensive PatientsPsychophysiology, 1981