Inaccuracy of mitral pressure half-time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance.
- 1 October 1988
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 78 (4) , 980-993
- https://doi.org/10.1161/01.cir.78.4.980
Abstract
Mitral pressure half-time (T1/2) is widely used as an independent measure of mitral valve area in patients undergoing percutaneous mitral valvotomy. However, fluid dynamics theory predicts T1/2 to be strongly dependent on chamber compliance and the peak transmitral gradient, which are variables that change dramatically with valvotomy. These theoretical predictions were tested in an in vitro model of the left heart where valve area, chamber compliance, and initial gradient were independently adjusted. Measured T1/2 was observed to vary inversely with orifice area and directly with net chamber compliance and the square root of the initial pressure gradient. Theoretical predictions of T1/2 agreed with observed values with r = 0.998. To test this theory in vivo, the hemodynamic tracings of 18 patients undergoing mitral valvotomy were reviewed. Predictions were made for T1/2 assuming dependence only on valve area; these showed some correlations before valvotomy (r = 0.48-0.64, p less than 0.05) but none after valvotomy (r = 0.05-0.28, p = NS). Predictions for T1/2 based on the theoretical derivation (and thus including compliance and pressure in their calculation) were much better: before valvotomy, r = 0.93-0.96, p less than 0.0001; after valvotomy, r = 0.52-0.66, p less than 0.05. These data indicate that T1/2 is not an independent inverse measure of mitral valve area but is also directly proportional to net chamber compliance and the square root of the initial transmitral gradient. These other factors render T1/2 an unreliable measure of mitral valve area in the setting of acute mitral valvotomy.This publication has 18 references indexed in Scilit:
- Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. IPublished by Elsevier ,2004
- Advances in the hemodynamic assessment of stenotic cardiac valvesJournal of the American College of Cardiology, 1987
- Calculations of cardiac valve stenosis: Restoring an old concept for advanced applicationsJournal of the American College of Cardiology, 1987
- When should doppler-determined valve area be better than the Gorlin formula?: Variation in hydraulic constants in low flow statesJournal of the American College of Cardiology, 1987
- Pressure-volume relationships in the pulmonary "venous" system in living dogs.Japanese Circulation Journal, 1987
- Interrelationship of mid-diastolic mitral valve motion, pulmonary venous flow, and transmitral flow.Circulation, 1986
- Effect of atrial fibrillation and mitral regurgitation on calculated mitral valve area in mitral stenosisThe American Journal of Cardiology, 1986
- Doppler echocardiographic evaluation of patients with porcine mitral valvesAmerican Heart Journal, 1986
- Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and Bioprosthetic (Hancock and Carpentier-Edwards) cardiac valvesThe American Journal of Cardiology, 1985
- Modified orifice equation for the calculation of mitral valve areaPublished by Elsevier ,1972