Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans
- 1 October 1997
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 83 (4) , 1383-1388
- https://doi.org/10.1152/jappl.1997.83.4.1383
Abstract
Rådegran, G. Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans. J. Appl. Physiol.83(4): 1383–1388, 1997.—Ultrasound Doppler has been used to measure arterial inflow to a human limb during intermittent static contractions. The technique, however, has neither been thoroughly validated nor used during dynamic exercise. In this study, the inherent problems of the technique have been addressed, and the accuracy was improved by storing the velocity tracings continuously and calculating the flow in relation to the muscle contraction-relaxation phases. The femoral arterial diameter measurements were reproducible with a mean coefficient of variation within the subjects of 1.2 ± 0.2%. The diameter was the same whether the probe was fixed or repositioned at rest (10.8 ± 0.2 mm) or measured during dynamic exercise. The blood velocity was sampled over the width of the diameter and the parabolic velocity profile, since sampling in the center resulted in an overestimation by 22.6 ± 9.1% (P< 0.02). The femoral arterial Doppler blood flow increased linearly (r = 0.997,P < 0.001) with increasing load [Doppler blood flow = 0.080 ⋅ load (W) + 1.446 l/min] and was correlated positively with simultaneous thermodilution venous outflow measurements (r = 0.996,P < 0.001). The two techniques were linearly related (Doppler = thermodilution ⋅ 0.985 + 0.071 l/min; r = 0.996,P < 0.001), with a coefficient of variation of ∼6% for both methods.Keywords
This publication has 16 references indexed in Scilit:
- Measurement of arterial blood flow by Doppler ultrasoundClinical Physics and Physiological Measurement, 1990
- Measurement of volume flow in the human common femoral artery using a duplex ultrasound systemUltrasound in Medicine & Biology, 1986
- Dynamic knee extension as model for study of isolated exercising muscle in humansJournal of Applied Physiology, 1985
- Maximal perfusion of skeletal muscle in man.The Journal of Physiology, 1985
- Measurement of blood flow by ultrasound: Accuracy and sources of errorUltrasound in Medicine & Biology, 1985
- Pulsed Doppler with B-mode imaging for quantitative blood flow measurementUltrasound in Medicine & Biology, 1979
- Leg Blood Flow during Exercise in ManClinical Science, 1971
- Muscle blood flow during exercise in normal man studied by the 133Xenon clearance methodCardiovascular Research, 1971
- Measurement of Blood Flow in the Femoral Artery in Man at Rest and during Exercise by Local ThermodilutionCirculation, 1964
- The blood flow through the human calf during rhythmic exerciseThe Journal of Physiology, 1949