Health implications of exposure to radiofrequency/microwave energies
- 1 May 1982
- journal article
- review article
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 39 (2) , 105-119
- https://doi.org/10.1136/oem.39.2.105
Abstract
The rapid development of and the increase in the number and variety of devices that emit microwave/radiofrequency (MW/RF) energies has resulted in a growing interest regarding the potential effects on health of these energies. The frequency ranges considered in this review are: 300 kHz to 300 MHz (radiofrequency) and 300 MHz to 300 GHz (microwaves). Investigations have shown that exposure to certain power densities for several minutes or hours can result in pathophysiological manifestations in laboratory animals. Such effects may or may not be characterised by a measurable rise in temperature, which is a function of thermal regulatory processes and active adaptation by the animal. The end result is either a reversible or irreversible change, depending on the irradiation conditions and the physiological state of the animal. At lower power densities, evidence of pathological changes or physiological alteration is non-existent or equivocal. Much discussion, nevertheless, has taken place on the relative importance of thermal or non-thermal effects of radiofrequency and microwave radiation. Several retrospective studies have been done on human populations exposed or believed to have been exposed to MW/RF energies. Those performed in the US have not shown any relationship of altered morbidity or mortality to MW/RF exposure. Reactions referrable to the central nervous system and cardiovascular effects from exposure of man to microwave energy have been reported mostly in Eastern European publications. Individuals suffering from various ailments or psychological factors may exhibit the same dysfunctions of the central nervous and cardiovascular systems as those reported to result from exposure to MW/RF; thus it is extremely difficult, if not impossible, to rule out other factors in attempting to relate MW/RF exposure to clinical conditions. There is a need to set limits on the amount of exposure to MW/RF energies that individuals can accept with safety. Operative protection standards have apparently provided adequate safety to workers and the general population to permit the use of MW/RF energies without harm or detriment.Keywords
This publication has 54 references indexed in Scilit:
- Microwaves modify thermoregulatory behavior in squirrel monkeyBioelectromagnetics, 1980
- Microwaves: Effect on Thermoregulatory Behavior in RatsScience, 1979
- Descriptive summary: Radiofrequency radiation dosimetry handbook—Second editionRadio Science, 1979
- Permeability of the blood-brain barrier to mannitol in the rat following 2450 MHz microwave irradiationBrain Research, 1979
- Studies on blood-brain barrier permeability after microwave-radiationRadiation and Environmental Biophysics, 1978
- Ocular Medical Surveillance on Microwave and Laser WorkersJournal of Occupational and Environmental Medicine, 1977
- Microwave alteration of the blood-brain barrier system of ratsBrain Research, 1977
- MICROWAVE EFFECTS ON THE BLOOD‐FORMING SYSTEM WITH PARTICULAR REFERENCE TO THE LYMPHOCYTEAnnals of the New York Academy of Sciences, 1975
- Effects of Exposure to Microwaves: Problems and PerspectivesEnvironmental Health Perspectives, 1974
- Effects of 800-MHz Electromagnetic Radiation on Body Weight, Activity, Hematopoiesis and Life Span in MiceHealth Physics, 1971