Aortic input impedance in heart failure: comparison with normal subjects and its changes during vasodilator therapy*
- 1 June 1984
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 5 (6) , 447-455
- https://doi.org/10.1093/oxfordjournals.eurheartj.a061690
Abstract
This study was aimed at the evaluation of aortic impedance in patients with congestive heart failure. Aortic impedance (simultaneous measurements of aortic pressure and blood flow), mean (Wm) and pulsatile (Wp) powers were compared in 11 normal subjects and in 12 patients with heart failure. Pulse wave velocity (C: modified Moens-Korteweg equation, simultaneous measurements of aortic pressure and radius) was determined under control conditions in all normal subjects and in 7 patients with heart failure. Impedance curves in patients with heart failure were characterized by increased values of the impedance modulus at 0 Hz (peripheral resistance) and at low frequencies. The characteristic impedance, C, and phase were not different from normal subjects. In six patients with heart failure, impedance curves were studied during nitroprusside infusion. During the infusion of the vasodilator, the impedance modulus at 0 Hz and at low frequencies decreased. The characteristic impedance was unchanged. The zero intercept of the phase was shifted towards lower frequencies. These results show that the changes in impedance curves in patients with heart failure are due to greater peripheral resistance and wave reflection. During nitroprusside infusion the stroke volume increased and the aortic blood flow became more pulsatile (greater values of low frequency components). This modification accounts for the increased values ofWm and Wp, and is related to decreased peripheral resistance and wave reflection.Keywords
This publication has 14 references indexed in Scilit:
- Aortic Input Impedance during Nitroprusside InfusionJournal of Clinical Investigation, 1979
- Effects of alterations in aortic input impedance on the force-velocity-length relationship in the intact canine heart.Circulation Research, 1979
- Study of left ventricular pressure-volume relations during nitroprusside infusion in human subjects without coronary artery disease.Heart, 1979
- Aortic input impedance in heart failure.Circulation, 1978
- Evaluation of the elasticity and characteristic impedance of the ascending aorta in manCardiovascular Research, 1978
- Vasodilator treatment for acute and chronic heart failure.Heart, 1977
- Input impedance of the systemic circulation in man.Circulation Research, 1977
- Input Impedance of the Systemic CirculationCirculation Research, 1967
- Hydraulic Power Associated with Pulmonary Blood Flow and its Relation to Heart RateCirculation Research, 1966
- Vascular Impedance of the Femoral BedCirculation Research, 1966