The total number of neurons in the human neocortex unbiasedly estimated using optical disectors
- 1 March 1990
- journal article
- research article
- Published by Wiley in Journal of Microscopy
- Vol. 157 (3) , 285-304
- https://doi.org/10.1111/j.1365-2818.1990.tb02967.x
Abstract
An efficient method is presented for obtaining, in under 4h, an unbiased estimate of the total number of neurons in the human neocortex, with a coefficient of error on the estimate of ∼ 5%. The novel sampling scheme used in this study is unbiased and was designed so that only a small amount of neocortical grey matter had to be removed. Hence, the majority of the cerebral grey matter and all the internal grey matter was left intact for further resampling and analysis. Each cerebral hemisphere was subdivided into the four major neocortical regions, sliced coronally at 7-mm intervals and the volume of the neocortex determined using Cavalieri's principle. Uniform sampling of neocortex was performed in the hemisphere followed by regional subsampling with a varying sampling fraction being taken from each region. Neuronal density estimates were made in thick plastic sections using optical disectors. Shrinkage estimates were made in parallel with the number estimates and found to be negligible. The total number of neocortical neurons in the right hemisphere of five normal 80-year-old men was found to be 13·7 × 109 with an inter-individual coefficient of variation of 12%.Keywords
This publication has 17 references indexed in Scilit:
- Optimizing sampling designs for volume measurements of components of human brain using a stereological methodJournal of Microscopy, 1989
- Unbiased estimation of particle number using sections—an historical perspective with special reference to the stereology of glomeruliJournal of Microscopy, 1989
- The new stereological tools: Disector, fractionator, nucleator and point sampled intercepts and their use in pathological research and diagnosisAPMIS, 1988
- The nucleatorJournal of Microscopy, 1988
- Some new, simple and efficient stereological methods and their use in pathological research and diagnosisAPMIS, 1988
- Stereology of arbitrary particles*Journal of Microscopy, 1986
- The unbiased estimation of number and sizes of arbitrary particles using the disectorJournal of Microscopy, 1984
- The effects of embedding in water-soluble plastics on the final dimensions of liver sectionsJournal of Microscopy, 1983
- Measuring error and sampling variation in stereology: comparison of the efficiency of various methods for planar image analysisJournal of Microscopy, 1981