Automatic retinal image registration scheme using global optimization techniques
- 1 March 1999
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Technology in Biomedicine
- Vol. 3 (1) , 47-60
- https://doi.org/10.1109/4233.748975
Abstract
Retinal image registration is commonly required in order to combine the complementary information in different retinal modalities. In this paper, a new automatic scheme to register retinal images is presented and is currently tested in a clinical environment. The scheme considers the suitability and efficiency of different image transformation models and function optimization techniques, following an initial preprocessing stage. Three different transformation models-affine, bilinear and projective-as well as three optimization techniques-downhill simplex method, simulated annealing and genetic algorithms-are investigated and compared in terms of accuracy and efficiency. The registration of 26 pairs of fluoroscein angiography and indocyanine green chorioangiography images with the corresponding red-free retinal images, showed the superiority of combining genetic algorithms with the affine and bilinear transformation models. A comparative study of the proposed automatic registration scheme against the manual method, commonly used in clinical practice, is finally presented showing the advantage of the proposed automatic scheme in terms of accuracy and consistency.Keywords
This publication has 38 references indexed in Scilit:
- Multidimensional Alignment Using the Euclidean Distance TransformGraphical Models and Image Processing, 1997
- Medical image matching-a review with classificationIEEE Engineering in Medicine and Biology Magazine, 1993
- Computer-aided interpretation of SPECT images of the brain using an MRI-derived 3D neuro-anatomical atlasMedical Informatics, 1991
- Motion displacement estimation using an affine model for image matchingOptical Engineering, 1991
- Analysis of the cost function used in simulated annealing for CT image reconstructionApplied Optics, 1990
- Principal warps: thin-plate splines and the decomposition of deformationsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1989
- Multiresolution elastic matchingComputer Vision, Graphics, and Image Processing, 1989
- Three-Dimensional Volumetric Reconstruction for Neuromagnetic Source LocalizationPublished by Springer Nature ,1989
- Anatomical Adjustments in Brain Positron Emission Tomography Using CT ImagesJournal of Computer Assisted Tomography, 1988
- Radiotherapy planning: direct tumor location on simulation and port films using CT. Part I. Principles.Radiology, 1986