Gravitational moment correction in isokinetic dynamometry using anthropometric data
- 1 July 1996
- journal article
- special communications
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 28 (7) , 900-907
- https://doi.org/10.1097/00005768-199607000-00018
Abstract
The purpose of this study was to compare different methods of gravity correction in isokinetic dynamometry. The gravitational moment of the left leg-foot segment of 25 males was measured on a Biodex dynamometer at 30° of knee flexion statically, and as the segment was passively falling from 0° to 90° with a constant velocity of 0.035 rad·s-1. The tests were performed in a supine and a seated position. The gravitational moments were also estimated from anthropometric data and directly, using a reaction board method that was considered as the criterion measurement. Furthermore, the isokinetic maximum moment output of the knee flexors and extensors was measured and corrected for gravity using the above methods at angular velocities of 0.52 rad·s-1 and 2.62 rad·s-1 during eccentric, and at 0.52 rad·s-1, 2.62 rad·s-1, and 4.71 rad·s-1 during concentric activations. One-way repeated-measures analysis of variance tests revealed significant differences (P < 0.05) between the gravitational moments obtained on the isokinetic dynamometer and those estimated from anthropometric data or by the reaction board method. The maximum extensor and flexor moments were significantly different, corrected using the gravity correction methods on the dynamometer relative to the anthropometric model or the reaction board (P < 0.05). These results suggest that the determination of gravitational moments based on anthropometric data is more accurate than current gravity correction methods. This new proposed method should be implemented in isokinetic dynamometry applications.Keywords
This publication has 18 references indexed in Scilit:
- Effect of hip position on gravity effect torqueMedicine & Science in Sports & Exercise, 1994
- Intertrial Reliability of Work Measurements Recorded During Concentric Isokinetic Knee Extension and Flexion in Subjects with and without Meniscal TearsPTJ: Physical Therapy & Rehabilitation Journal, 1991
- Exercise-Induced Muscle Soreness After Concentric and Eccentric Isokinetic ContractionsPTJ: Physical Therapy & Rehabilitation Journal, 1991
- Sources of Error in Isokinetic Dynamometry: Effects of Visual Feedback on Maximum Torque MeasurementsJournal of Orthopaedic & Sports Physical Therapy, 1991
- Test-Retest Reliability of the Biodex Isokinetic DynamometerJournal of Orthopaedic & Sports Physical Therapy, 1990
- Isokinetic DynamometrySports Medicine, 1989
- Effect of Stabilization on Maximal Isokinetic Torque of the Quadriceps Femoris Muscle During Concentric and Eccentric ContractionsPTJ: Physical Therapy & Rehabilitation Journal, 1988
- Effects of Speed, Hip and Knee Angle, and Gravity on Hamstring-to-Quadriceps Torque RatiosJournal of Orthopaedic & Sports Physical Therapy, 1988
- Influence of Position on Knee Flexor Peak TorqueJournal of Orthopaedic & Sports Physical Therapy, 1988
- Progressive Resistance Exercise for Injury Rehabilitation Special Emphasis on Isokinetic TrainingSports Medicine, 1985