An adequate strategy for the thermodilution technique in patients during mechanical ventilation
- 1 July 1990
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 16 (7) , 422-425
- https://doi.org/10.1007/bf01711218
Abstract
The application of the thermodilution method in conditions associated with variations in blood flow implies a misuse of the Stewart Hamilton equation. Therefore, we studied the reliability of the thermodilution method for the estimation of mean cardiac output (CO) during mechanical ventilation in patients (n=9). Variation of the injection moment in the ventilatory cycle elicited a cyclic variation of CO estimates. This variation was not the same for all patients neither in phase nor in amplitude. Therefore, no specific phase in the ventilatory cycle could be selected for an accurate estimation of mean CO. Averaging CO estimates randomly distributed in the ventilatory cycle led to an improvement of accuracy with the square root of the number of observations. The averaging of CO estimates spread equally over the ventilatory cycle led to a much better result, e.g., the variation in the average of two estimates equally spread in the ventilatory cycle was similar to the variation in the average of four random estimates. We conclude that averaging of 3 or 4 estimates spread equally over the ventilatory cycle is an adequate strategy to estimate mean cardiac output in patients reliably.Keywords
This publication has 13 references indexed in Scilit:
- Extrapolation of thermodilution curves obtained during a pause in artificial ventilationJournal of Applied Physiology, 1987
- Effects of intermittent positive-pressure ventilation on cardiac output measurements by thermodilutionCritical Care Medicine, 1986
- Improvement of cardiac output estimation by the thermodilution method during mechanical ventilationIntensive Care Medicine, 1986
- Thermodilution Cardiac Output MeasurementPublished by American Medical Association (AMA) ,1985
- Thermodilution cardiac output measurement. Effects of the respiratory cycle on its reproducibilityJAMA, 1985
- Effects of mechanical ventilation on the measurement of cardiac output by thermodilutionCritical Care Medicine, 1982
- RELIABILITY OF THE THERMODILUTION METHOD IN THE DETERMINATION OF CARDIAC-OUTPUT IN CLINICAL-PRACTICEPublished by Elsevier ,1982
- Effects of the respiratory cycle on cardiac output measurementsCritical Care Medicine, 1981
- Limitations of thermal dilution curves for cardiac output determinations.Journal of Applied Physiology, 1971
- Hemodynamic Effects of Intermittent Positive Pressure RespirationAnesthesiology, 1966