Subcutaneous glucose sensor values closely parallel blood glucose during insulin‐induced hypoglycaemia
- 10 March 2003
- journal article
- research article
- Published by Wiley in Diabetic Medicine
- Vol. 20 (3) , 238-241
- https://doi.org/10.1046/j.1464-5491.2003.00837.x
Abstract
Aims To assess the accuracy of the Minimed continuous glucose monitoring system (CGMS) in estimating blood glucose concentration during a controlled reduction in blood glucose. Research design and methods We studied nine adolescent diabetics (age 14 ± 1.5 years) wearing the CGMS during hyperinsulinaemic hypoglycaemic clamp studies. The glucose values obtained by the CGMS were compared with the venous blood samples taken during the studies and measured at the bedside using a glucose oxidase technique. Results Blood glucose was lowered from euglycaemia to a mean of 2.8 mmol/l over 120 min and maintained at that level for a further 40 min. A total of 429 paired glucose measurements were available for analysis. Analysis using weighted Deming regression and t‐tests revealed small differences between the methods, with blood glucose levels slightly higher than interstitial fluid levels. The mean difference across all values was 0.13 mmol/l. The observed difference was greatest at blood glucose values < 3.3 mmol/l. Conclusions This study suggests that during a fall in systemic glucose the subcutaneous glucose sensor provides an accurate reflection of blood glucose. However, a small difference is apparent at blood glucose values < 3.3 mmol/l. Diabet. Med. 20, 238–241 (2003)Keywords
This publication has 22 references indexed in Scilit:
- Detection of Hypoglycaemia by Microdialysis - Measurements of Glucose in Subcutaneous Adipose TissueHormone and Metabolic Research, 1997
- Microdialysis in Adipose Tissue and Skeletal MuscleHormone and Metabolic Research, 1997
- Self-Monitoring of Blood Glucose in Type I Diabetic Patients: Comparison With Continuous Microdialysis Measurements of Glucose in Subcutaneous Adipose Tissue During Ordinary Life ConditionsDiabetes Care, 1997
- Subcutaneous Glucose Concentration in Humans: Real estimation and continuous monitoringDiabetes Care, 1995
- Interstitial fluid concentrations of glycerol, glucose, and amino acids in human quadricep muscle and adipose tissue. Evidence for significant lipolysis in skeletal muscle.Journal of Clinical Investigation, 1995
- Combination of Microdialysis and Glucose Sensor for Continuous On Line Measurement of the Subcutaneous Glucose Concentration: Theory and Practical ApplicationHormone and Metabolic Research, 1994
- Clinical Usefulness of the Glucose Concentration in the Subcutaneous Tissue - Properties and Pitfalls of Electrochemical BiosensorsHormone and Metabolic Research, 1994
- Glucose Concentration in Subcutaneous Extracellular SpaceDiabetes Care, 1993
- On Line Continuous Monitoring of Subcutaneous Tissue Glucose is Feasible by Combining Portable Glucosensor with MicrodialysisHormone and Metabolic Research, 1993
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987