Convergence of the maximum likelihood reconstruction algorithm for emission computed tomography
- 1 April 1987
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 32 (4) , 463-476
- https://doi.org/10.1088/0031-9155/32/4/005
Abstract
Convergence properties of the maximum likelihood estimator (MLE) for emission computed tomographic (ECT) image reconstruction are evaluated as a function of Poisson noise, precision of the assumed system resolution model and iteration number up to 10000 iterations. In the ECT reconstruction problem, the photon-emitting source distribution is to be estimated from measurements of projections of the emitted photon flux. The MLE algorithm seeks a source distribution which will maximise the maximum likelihood function relating the estimated and the measured projections. A Monte Carlo model of the system transfer function of a single photon emission computed tomographic (SPECT) system allowed realistic projection data to be simulated from a known source distribution. Poisson noise was added to the Monte Carlo simulations. By using projection data from a known source distribution generated through a known system transfer function, the authors were able to simultaneously evaluate the convergence of both the projection estimations as well as the source distribution estimations. As predicted by theory, the estimates of the projections did continue to improve (or remain the same) for all combinations of Poisson noise (up to 10% RMS) and system resolution (+or-10% of true value) tested. Convergence of source distribution estimates to the true value was found for up to 10000 iterations only for low noise (0.1% RMS) with the correct resolution function. For all other combinations, there was some optimum iteration (between 30 and 400) after which the source estimate was degraded even though the estimate of the projections was improved.This publication has 18 references indexed in Scilit:
- Accelerated Iterative Reconstruction for Positron Emission Tomography Based on the EM Algorithm for Maximum Likelihood EstimationIEEE Transactions on Medical Imaging, 1986
- A Statistical Model for Positron Emission TomographyJournal of the American Statistical Association, 1985
- Matrix-Based Image Reconstruction Methods for TomographyIEEE Transactions on Nuclear Science, 1985
- Inverse Monte Carlo: A Unified Reconstruction Algorithm for SPECTIEEE Transactions on Nuclear Science, 1985
- Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigationPhysics in Medicine & Biology, 1984
- Maximum Likelihood PET with Real DataIEEE Transactions on Nuclear Science, 1984
- Image Reconstruction from List-Mode Data in an Emission Tomography System Having Time-of-Flight MeasurementsIEEE Transactions on Nuclear Science, 1983
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982
- Analysis of SPECT including Scatter and Attenuation Using Sophisticated Monte Carlo Modeling MethodsIEEE Transactions on Nuclear Science, 1982
- A Maximum Likelihood Approach to Emission Image Reconstruction from ProjectionsIEEE Transactions on Nuclear Science, 1976