Observations of thermal gradients in perfused tissues during water bath heating
- 1 January 1992
- journal article
- research article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 8 (2) , 275-287
- https://doi.org/10.3109/02656739209021782
Abstract
Actual thermal gradients in perfused tissues are difficult to observe using thermocouples because of thermal conduction along the probes. We have used fine type-K (chromelalumel) probes, which have a much lower thermal conductivity than equivalent-sized type-T (copper-constantan) thermocouples, to examine thermal gradients in two mouse tumour systems during water bath heating. The results indicate substantial heterogeneity in temperature distribution even in tumours transplanted in the foot and immersed to a depth of 2 cm in a 44°C water bath for 20 min, i.e. thermal gradients greater than 1 °C/mm were observed in KHT fibrosarcomas. The temperature heterogeneity for water bath heating is primarily a result of blood flow and appears to be tumour-specific. Temperature measurements using an excised perfused canine kidney demonstrate that increased perfusate volume flow increases the range of tissue temperatures. Consistent with theory, an artifactual improvement in temperature homogeneity resulted when temperature was measured using type-T thermocouples instead of type-K probes. These results emphasize the difficulties in obtaining accurate temperature measurements during experimental and clinical hyperthermia. Even extensive measurements of temperature in tissues may underestimate the true range of heterogeneity unless factors such as thermal smearing are controlled.Keywords
This publication has 22 references indexed in Scilit:
- RTOG quality assurance guidelines for clinical trials using hyperthermiaInternational Journal of Radiation Oncology*Biology*Physics, 1990
- Winner of the 1988 Lund Science Award: Hydralazine-induced enhancement of hyperthermic damage in a C3H mammary carcinomain vivoInternational Journal of Hyperthermia, 1989
- Thermochemotherapyin vivoof a C3H mouse mammary carcinoma: Thermotolerant tumoursInternational Journal of Hyperthermia, 1989
- Evaluation of equipment for hyperthermic treatment of cancerInternational Journal of Hyperthermia, 1988
- EditorialInternational Journal of Hyperthermia, 1987
- The practical use of thermocouples for temperature measurement in clinical hyperthermiaInternational Journal of Hyperthermia, 1986
- Thermal conduction errors of manganin-constantan thermocouple arraysPhysics in Medicine & Biology, 1985
- Thermal conductivity and H2O content in rabbit kidney cortex and medullaJournal of Thermal Biology, 1983
- The response of six mouse tumours to combined heat and X rays: implications for therapyThe British Journal of Radiology, 1979
- The influence of blood flow on temperature distribution in the exteriorized mouse intestine during treatment by hyperthermiaThe British Journal of Radiology, 1979