Bestimmung des Herzminutenvolumens durch Impedanzkardiographie: Ein Weg zur Prophylaxe der Frühgeburtlichkeit?

Abstract
30 gravid women between the ages of 18 and 38 years who had gone into premature labour of unknown etiology were examined with respect to cardiac output and various other cardiovascular parameters in the standing, supine and left lateral positions. Measurements were carried out using an impedance-cardiograph. A group of 30 women of similar age and duration of pregnancy but not in premature labour was also tested as controls. In the standing position, the test group showed a cardiac output which was 15% less than that of the controls. Statistically this was highly significant (pp<0,005). Im Liegen war zwischen den beiden Gruppen kein Unterschied festzustellen. Die Untersuchung stimmt mit den aus der Literatur bekannten Ergebnissen überein. Neu ist die Bestimmung der Kreislaufparameter mit einer nichtinvasiven, strahlenbelastungsfreien Methode. Ihre praktische Anwendung könnte zu einer Reduktion der Frühgeburtlichkeit beitragen. Die kreislaufphysiologischen Grundlagen in der Schwangerschaft werden diskutiert.