Automatic determination of LV orientation from SPECT data
- 1 March 1995
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 14 (1) , 88-99
- https://doi.org/10.1109/42.370405
Abstract
Presents a new method to determine the orientation or pose of the left ventricle (LV) of the heart from cardiac SPECT (single photon emission computed tomography) data. This proposed approach offers an accurate, fast, and robust delineation of the LV long-axis. The location and shape of the generated long-axis can then be utilized to define automatically the tomographic slices for enhanced visualization and quantification of the clinical data. The methodology is broadly composed of two main steps: (1) volume segmentation of cardiac SPECT data; and (2) topological goniometry, a novel approach incorporating volume visualization and computer graphics ideas to determine the overall shape of 3-D objects. The outcome of the algorithm is a 3-D curve representing the overall pose of the LV long-axis. Experimental results on both phantom and clinical data (50 technetium-99m and 74 thallium-201) are presented. An interactive graphical interface to visualize the volume (3-D) data, the left ventricle, and its pose is an integral part of the overall methodology. This technique is completely data driven and expeditious, making it viable for routine clinical use.Keywords
This publication has 29 references indexed in Scilit:
- A survey of algorithms for volume visualizationACM SIGGRAPH Computer Graphics, 1992
- A bending energy model for measurement of cardiac shape deformityIEEE Transactions on Medical Imaging, 1991
- Automatic assignment of elliptical ROIs: First results in planar scintigrams of the left ventricleEuropean Journal of Nuclear Medicine and Molecular Imaging, 1989
- Pose determination of a three-dimensional object using triangle pairsIEEE Transactions on Pattern Analysis and Machine Intelligence, 1988
- Delineating Elliptical Objects with an Application to Cardiac ScintigramsIEEE Transactions on Medical Imaging, 1987
- 3D reconstruction of the brain from magnetic resonance images using a connectivity algorithmMagnetic Resonance Imaging, 1987
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979
- Three-dimensional display of human organs from computed tomogramsComputer Graphics and Image Processing, 1979
- Optimal surface reconstruction from planar contoursCommunications of the ACM, 1977
- Approximating Complex Surfaces by Triangulation of Contour LinesIBM Journal of Research and Development, 1975