The Role of Electrode Size on the Incidence of Spreading Depression and on Cortical Cerebral Blood Flow as Measured by H2 Clearance
- 1 March 1992
- journal article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 12 (2) , 230-237
- https://doi.org/10.1038/jcbfm.1992.33
Abstract
Cerebral blood flow was measured by the H2 clearance method 30 and 60 min after the implantation of 300, 250, 125, or 50 μm diameter platinum–iridium electrodes 2 mm deep into the right parietal cortex of normothermic, normocarbic halothane-anesthetized rats. Another group of animals had 50 μm electrodes inserted 1 mm. In all animals, the presence or absence of a wave of spreading depression (SD) was noted at the time of implantation, with recordings made with glass micropipettes. H2 flow values were compared with those measured in gray matter from the same anatomical region (but from different rats), using [3H]nicotine. The incidence of SD ranged from 60% following insertion of 300 μm electrodes to 0% with 50 μm electrodes. H2 clearance flows also varied with electrode size, from 77 ± 21 ml 100 g−1 min−1 (mean ± standard deviation) with 300 μm electrodes to 110 ± 31 and 111 ± 16 ml 100 g−1 min−1 with 125 and 50 μm electrodes, respectively (insertion depth of 2 mm). A CBF value of 155 ± 60 ml 100 g−1 min−1 was obtained with 50 μm electrodes inserted only 1 mm. Cortical gray matter blood flow measured with [3H]nicotine was 154 ± 35 ml 100 g−1 min−1. When the role of SD in subsequent flow measurements was examined, there was a gradual increase in CBF between 30 and 60 min after electrode insertion in those animals with SD, while no such change was seen in rats without SD. These results indicate that the choice of electrode size and implantation depth influences the measurement of CBF by H2 clearance. CBF values equivalent to those obtained with isotopic techniques can be acutely obtained with small (50 μm diameter) electrodes inserted 1 mm into the cortex. While the occurrence of SD does influence CBF in the period immediately after implantation, a relationship between electrode size and measured flow is present that is independent of SD.Keywords
This publication has 19 references indexed in Scilit:
- REGIONAL CLEARANCE OF HYDROGEN AS A MEASURE OF CEREBRAL BLOOD FLOWActa Neurologica Scandinavica, 2009
- Regional Cerebral Blood Flow during Spreading Cortical Depression in Conscious RatsJournal of Cerebral Blood Flow & Metabolism, 1991
- Serial determinations of regional cerebral blood flow in the rat using simple chronically implanted platinum wire microelectrodesJournal of Neuroscience Methods, 1989
- Regional Cerebral Glucose Phosphorylation and Blood Flow After Insertion of a Microdialysis Fiber Through the Dorsal Hippocampus in the RatJournal of Neurochemistry, 1987
- Long-Lasting Reduction of Cortical Blood Flow of the Rat Brain after Spreading Depression with Preserved Autoregulation and Impaired CO2 ResponseJournal of Cerebral Blood Flow & Metabolism, 1984
- Cerebral ischemia produced by four-vessel occlusion in the rat: a quantitative evaluation of cerebral blood flow.Stroke, 1982
- Extracellular ion concentrations during spreading depression and ischemia in the rat brain cortexActa Physiologica Scandinavica, 1981
- Cortical cellular response in acute subarachnoid hemorrhageJournal of Neurosurgery, 1980
- Regional blood flow in deep structures of the brain measured in acute cat experiments by means of a new beta-sensitive semiconductor needle detectorExperimental Brain Research, 1967
- Measurement of Local Blood Flow with Hydrogen GasCirculation Research, 1964