Current allergic asthma and rhinitis: diagnostic efficiency of three commonly used atopic markers (IgE, skin prick tests, and Phadiatop®)
- 1 June 1998
- Vol. 53 (6) , 608-613
- https://doi.org/10.1111/j.1398-9995.1998.tb03937.x
Abstract
Total serum IgE, Phadiatop®, and the skin prick test (SPT) are commonly used to diagnose atopic diseases. However, no large study has ever been done to test their diagnostic efficiency. We studied the diagnostic value of these three atopic markers in 8329 well‐randomized adults from the Swiss Population Registry. The prevalence of current allergic asthma (CAA) was 1.8% and of current allergic rhinitis (CAR) 16.3%. The prevalences of positive Phadiatop, positive SPT (at least, one out of eight SPT to common aeroallergens with a wheal of >3 mm), and positive total IgE (IgE >100 kU/1) were 29, 23, and 23%, respectively. To diagnose CAA and CAR. the sensitivity of Phadiatop was significantly higher than that of SPT (72.5% vs 65.4%, 77.1% vs 68.4% respectively; P<0.01 and <0.001) and IgE (72.5% VA‐ 56.9%, 77.1% vs 43.9%, respectively; both p<0.001). The sensitivity of SPT was significantly higher (68.4% vs 43.9% P<0.001) than that of IgE to diagnose CAR. When CAA and CAR were excluded, the SPT specificity was significantly higher than that of Phadiatop (77.8% vs 71.9% and 85.9% vs 80.5%, respectively; both P<0.001): when CAR was excluded, SPT was significantly higher than IgE (85.9 vs 81.4%; P<0.001). SPT had significantly the best positive predictive value for CAA (5.2% for SPT vs 4.6% for both IgE and Phadiatop; both P<0.001) and CAR (48.7% for SPT vs 43.5% for Phadiatop and 31.6% for IgE; both P<0.001). The three markers of atopy had roughly the same negative predictive value (NPV) for CAA, but IgE had a significantly lower NPV for CAR than SPT and Phadiatop (88.1% vs 93.3% and 94.7%, respectively; both P<0.001). The diagnostic efficiency of SPT was significantly higher than that of Phadiatop (83.1% vs 79.9% and 77.6 vs 71.9%, respectively; both F<0.001) to diagnose CAR and CAA. IgE and SPT had equal efficiency (77.6%), which was significantly higher than that of Phadiatop, to diagnose CAA (71.9%; both P<0.001). In conclusion, SPT have the best positive predictive value and the best efficiency to diagnose respiratory atopic diseases. Furthermore, SPT give information on sensitivity to individual allergens and should therefore be used primarily by clinicians to assess respiratory allergic diseases. Moreover, they are cheaper and provide immediate, educational information for both patient and physician.Keywords
This publication has 17 references indexed in Scilit:
- SAPALDIA: Methods and participation in the cross-sectional part of the Swiss Study on Air Pollution and Lung Diseases in AdultsInternational Journal of Public Health, 1997
- The use of in vitro tests for IgE antibody in the specific diagnosis of IgE-mediated disorders and in the formulation of allergen immunotherapyJournal of Allergy and Clinical Immunology, 1992
- Reliability of respiratory symptoms to diagnose atopyClinical and Experimental Allergy, 1991
- Allergy screening with Phadiatop® and CAP Phadiatop® in combination with a questionnaire in adults with asthma and rhinitisAllergy, 1990
- Evaluation of the Phadiatop® test in an epidemiological studyAllergy, 1990
- Value of a new screening test for respiratory allergyAllergy, 1988
- Prevalence of Bronchial Hyperresponsiveness in Children: The Relationship between Asthma and Skin Reactivity to Allergens in Two CommunitiesInternational Journal of Epidemiology, 1986
- IgE Concentrations Measured by PRIST® in Serum of Healthy Adults and in Patients with Respiratory AllergyAllergy, 1981
- Nonspecificity of the bronchoconstricting effect of histamine and acetyl-beta-methylcholine in patients with obstructive airway diseaseJournal of Allergy, 1966
- Comparative action of acetyl-beta-methylcholine, histamine, and pollen antigens in subjects with hay fever and patients with bronchial asthmaJournal of Allergy, 1965