Segmentation with gray‐scale connectedness can separate arteries and veins in MRA
Open Access
- 27 March 2002
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 15 (4) , 438-445
- https://doi.org/10.1002/jmri.10047
Abstract
Purpose To describe and present some preliminary results for a novel algorithm for segmentation with gray‐scale connectedness as a means to separate arteries and veins in magnetic resonance angiography (MRA). Materials and Methods The proposed algorithm, SeparaSeed, uses the gray‐scale degree of connectedness as a tool to find the zone surrounding each vessel, in order to split the original volume into its different vessel components. In contrast to traditional segmentation methods, no gray‐scale information is lost in the process. The segmentation is performed in one step, resulting in a partition of the initial volume into a chosen number of regions of interest (ROIs). Finally, visualization is achieved by projecting the 3D vessel trees to 2D using the common maximum intensity projection (MIP). The algorithm was tested in two MRA data sets of the vessels of the pelvis acquired after injection of an intravascular contrast agent and in one data set of the vessels of the neck with gadolinium. Results In all data sets, a large proportion of the venous signal was removed while preserving that of the arteries, thus improving visualization of the relevant vessels. Conclusion Separation of arteries and veins is feasible with the proposed algorithm with a moderate amount of interaction. J. Magn. Reson. Imaging 2002;15:438–445.Keywords
This publication has 16 references indexed in Scilit:
- Model-Based Detection of Tubular Structures in 3D ImagesComputer Vision and Image Understanding, 2000
- Scale-Based Fuzzy Connected Image Segmentation: Theory, Algorithms, and ValidationComputer Vision and Image Understanding, 2000
- A DOUBLE COAXIAL DELIVERY SYSTEM FOR DEPLOYMENT OF A TWO-STAGE STENT-GRAFT: An experimental feasibility studyActa Radiologica, 2000
- High-Resolution Imaging of Coronary Calcifications by Intense Low-Energy Fluoroscopic X-Ray Obtained from Synchrotron RadiationActa Radiologica, 2000
- Multiple sclerosis lesion quantification using fuzzy-connectedness principlesIEEE Transactions on Medical Imaging, 1997
- On Digital Distance Transforms in Three DimensionsComputer Vision and Image Understanding, 1996
- CT angiography.American Journal of Roentgenology, 1995
- Extraction of intensity connectedness for image processingPattern Recognition Letters, 1995
- MR Angiography with Gradient Motion RefocusingJournal of Computer Assisted Tomography, 1988
- Fuzzy digital topologyInformation and Control, 1979