Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography
- 18 March 2005
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 15 (7) , 1432-1440
- https://doi.org/10.1007/s00330-004-2582-z
Abstract
This study aimed to assess the feasibility of cardiac global function evaluation during a whole-chest multi-slice CT (MSCT) acquisition in patients referred for suspicion of pulmonary embolism (PE), and to compare the results with planar equilibrium radionuclide ventriculography (ERNA). Ten consecutive haemodynamically stable patients (six female, four male; mean age 69.7 years; heart rate 65–99 bpm) with suspicion of PE underwent an MSCT and ERNA within a 6 h period. CT acquisition was performed after contrast medium injection by using 16×1.5 mm collimation and retrospective ECG gating. Left ventricular (LVEF) and right ventricular (RVEF) ejection fractions were calculated using dedicated three-dimensional software. Relationships between measurements obtained with MSCT and ERNA were assessed using linear regression analysis and reliability of MSCT was assessed with intra-class correlation coefficient. Bland–Altman analysis was performed to calculate limits of agreement between MSCT and ERNA. MSCT was performed successfully in ten patients with a mean acquisition time of 16.5±2.8 s. Functional cardiac evaluation was possible on CT for all patients except for one due to poor opacification of right ventricle. Linear regression analysis showed a good correlation between MSCT and ERNA for the LVEF (R=0.91) and the RVEF (R=0.89) measurements. Intra-class correlation was superior for LVEF (0.92) than for the RVEF (0.68). Bland–Altman plots demonstrated that MSCT substantially overestimated the ERNA RVEF. Morphological CT data demonstrated PE in four of ten of patients and alternative diagnoses in five of ten patients. Our study reveals that MSCT with retrospective ECG gating may provide in one modality a morphological and a functional cardiopulmonary evaluation. Comparison with ERNA demonstrated a good correlation for both ventricular ejection fractions.Keywords
This publication has 40 references indexed in Scilit:
- Multislice spiral computed tomography coronary angiography in patients with stable angina pectorisJournal of the American College of Cardiology, 2004
- Right Ventricular Enlargement on Chest Computed TomographyCirculation, 2004
- Spiral Computed Tomography for Acute Pulmonary EmbolismCirculation, 2004
- Heparin plus Alteplase Compared with Heparin Alone in Patients with Submassive Pulmonary EmbolismNew England Journal of Medicine, 2002
- EditorialJournal of the American College of Cardiology, 1997
- Severity Assessment of Acute Pulmonary Embolism with Spiral CTJournal of Thoracic Imaging, 1997
- Radionuclide ventriculography for assessment of absolute right and left ventricular volumes in children.Circulation, 1982
- Use of equilibrium (gated) radionuclide ventriculography to quantitate left ventricular output in patients with and without left-sided valvular regurgitation.Circulation, 1981
- First-pass radionuclide assessment of right and left ventricular performance in patients with cardiac and pulmonary diseaseSeminars in Nuclear Medicine, 1979
- A new technique for assessing right ventricular ejection fraction using rapid multiple-gated equilibrium cardiac blood pool scintigraphy. Description, validation and findings in chronic coronary artery disease.Circulation, 1979