Ultrasound synthetic aperture imaging: monostatic approach
- 1 May 1994
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 41 (3) , 333-339
- https://doi.org/10.1109/58.285467
Abstract
An ultrasound synthetic aperture imaging method based on a monostatic approach was studied experimentally. The proposed synthetic aperture method offers good dynamical resolution along with fast numerical reconstruction. In this study complex object data were recorded coherently in a two-dimensional hologram using a 3.5 MHz single transducer with a fairly wide-angle beam. Image reconstruction which applies the wavefront backward propagation method and the near-field curvature compensation was performed numerically in a microcomputer using the spatial frequency domain. This approach allows an efficient use of the FFT-algorithms. Because of the simple and fast scanning scheme and the efficient reconstruction algorithms the method can be made real-time. The image quality of the proposed method was studied by evaluating the spatial and dynamical resolution in a waterbath and in a typical tissue-mimicking phantom. The lateral as well as the range resolution (-6 dB) were approximately 1 mm in the depth range of 30-100 mm. The dynamical resolution could be improved considerably when the beam width was made narrower. Although it resulted in a slightly reduced spatial resolution this compromise has to be done for better resolution of low-contrast targets such as cysts. The study showed that cysts as small as 2 mm by diameter could be resolved.<>Keywords
This publication has 11 references indexed in Scilit:
- Frequency domain compensation for inhomogeneous layers in ultrasound holographyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1989
- Real-Time Digital Image Reconstruction: A Description of Imaging Hardware and an Analysis of Quantization ErrorsIEEE Transactions on Sonics and Ultrasonics, 1984
- Beam Steering with Linear ArraysIEEE Transactions on Biomedical Engineering, 1983
- Acoustic Imaging by Wave Field Extrapolation Part II: Practical AspectsPublished by Springer Nature ,1982
- A Real-Time Synthetic Aperture Digital Acoustic Imaging SystemPublished by Springer Nature ,1982
- B-scan Fourier transform holographyNDT International, 1979
- An Experimental 2 MHz Synthetic Aperture Sonar System Intended for Medical UseIEEE Transactions on Sonics and Ultrasonics, 1974
- Reconstruction of Ultrasonic Images by Backward PropagationPublished by Springer Nature ,1971
- Computer Reconstruction of Images from Ultrasonic HologramsPublished by Springer Nature ,1970
- Digital Image Formation from Detected Holographic DataPublished by Springer Nature ,1969