Recombinant hirudin in patients with chronic, stable coronary artery disease. Safety, half-life, and effect on coagulation parameters.
- 1 November 1993
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 88 (5) , 2015-2022
- https://doi.org/10.1161/01.cir.88.5.2015
Abstract
BACKGROUND Because the specific antithrombin hirudin prevents platelet-rich arterial thrombus and accelerates thrombolysis in a variety of animal models, it has promise as antithrombotic therapy. We therefore studied the half-life, effect on anticoagulant parameters, and safety of hirudin in patients with coronary artery disease. METHODS AND RESULTS Thirty-eight men and 1 woman (age [mean +/- SD], 60.4 +/- 6.9 years) with angiographic coronary disease were allocated in a single-blind ascending dosage study to a 6-hour i.v. infusion of recombinant hirudin (CGP 39,393) or matching placebo. The median terminal half-life for hirudin, measured by ELISA, was 2.7, 2.3, 2.9, 3.1, and 2.0 hours for the 0.02, 0.05, 0.1, 0.2, and 0.3 mg.kg-1 x h-1 groups, respectively. Activated partial thromboplastin times (aPTT) at 3, 4, and 6 hours were averaged into a plateau value. The aPTT plateau-to-baseline ratios were 1.5 +/- 0.1, 2.0 +/- 0.1, 2.3 +/- 0.1, 2.7 +/- 0.1, and 2.9 +/- 0.1, respectively, with hirudin infused at 0.02, 0.05, 0.1, 0.2, and 0.3 mg.kg-1 x h-1. From 62% to 77% of the aPTT plateau value was seen within 30 minutes of starting the infusions and was directly related to dose. The aPTT-to-baseline ratios correlated well with plasma hirudin levels (r = .88), whereas poor correlation and sensitivity were observed between plasma hirudin levels and activated coagulation time (ACT)-to-baseline ratios (r = .44). Plasma levels of hirudin and ACT in seconds correlated overall well (r = .80), but considerable overlap occurred between baseline ACT and ACT at plasma hirudin concentrations < 1000 ng/mL. Prothrombin times were significantly prolonged only at a dosage of > or = 0.05 mg.kg-1 x h-1 and were 11.8 +/- 0.5 (INR = 1.0), 12.3 +/- 0.7 (INR = 1.1), 13.3 +/- 1.2 (INR = 1.4), 14.2 +/- 0.4 (INR = 1.7), and 15.8 +/- 0.9 (INR = 2.3) seconds for each respective hirudin dosage. Thrombin times were beyond range (> 600 seconds) at 6 hours in all except 2 patients who received the lowest dosage. All parameters returned to baseline between 8 and 18 hours after the infusion. Bleeding times were not significantly prolonged. No side effects occurred. No antibodies to hirudin were detected 2 weeks after the infusion. CONCLUSIONS Recombinant hirudin has a terminal half-life of 2 to 3 hours. The aPTT correlates well with plasma levels of hirudin and allows close titration over a wide range of anticoagulation, while ACT and prothrombin time are relatively insensitive for monitoring hirudin administration. At anticoagulant levels effective in experimental thrombosis, a 6-hour infusion of hirudin is well tolerated and safe in a predominantly male group of patients with stable coronary atherosclerosis.Keywords
This publication has 36 references indexed in Scilit:
- Evidence for a rebound coagulation phenomenon after cessation of a 4-hour infusion of a specific thrombin inhibitor in patients with unstable angina pectorisJournal of the American College of Cardiology, 1993
- Anticoagulant effects of hirulog, ∗∗Hirulog™ brand direct thrombin inhibitor. a novel thrombin inhibitor, in patients with coronary artery diseaseThe American Journal of Cardiology, 1993
- The Pathogenesis of Coronary Artery Disease and the Acute Coronary SyndromesNew England Journal of Medicine, 1992
- Intravenous recombinant soluble human thrombomodulin prevents venous thrombosis in a rat modelJournal of Vascular Surgery, 1991
- Influence of heparin therapy on percutaneous transluminal coronary angioplasty outcome in patients with coronary arterial thrombusThe American Journal of Cardiology, 1990
- Application of thrombin-antithrombin III complex for detecting a latent hypercoagulable state in patients with coronary artery disease.Japanese Circulation Journal, 1989
- Aging-associated changes in indices of thrombin generation and protein C activation in humans. Normative Aging Study.Journal of Clinical Investigation, 1987
- Deep arterial injury during experimental angioplasty: Relation to a positive indium-111-labeled platelet scintigram, quantitative platelet deposition and mural thrombosisJournal of the American College of Cardiology, 1986
- In vivo quantitation of platelet deposition on human peripheral arterial bypass grafts using indium-111-labeled plateletsThe American Journal of Cardiology, 1983
- Morphology after Transluminal Angioplasty in Human BeingsNew England Journal of Medicine, 1981