Closure of midline laparotomy incisions with polydioxanone and nylon: The importance of suture technique
- 1 November 1994
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 81 (11) , 1606-1608
- https://doi.org/10.1002/bjs.1800811114
Abstract
The healing of midline laparotomy incisions closed with a continuous suture of nylon or second‐generation polydioxanone was evaluated in a randomized clinical trial. The effect of suture technique, reflected in the suture length to wound length ratio, was also assessed. All patients who underwent abdominal surgery through a midline incision were included except those with incisional hernia after previous midline operation. Wound dehiscence occurred in five (0·6 per cent) of 813 patients and wound infection in 73 (9·0 per cent). These rates were similar for both suture materials, as were those for the development of suture sinus and prolonged postoperative wound pain. Incisional hernia 12 months after surgery was found in 49 (15·1 per cent) of 325 wounds sutured with polydioxanone and in 50 (15·7 per cent) of 318 closed with nylon (P=0·91). There was a significant correlation between the hernia rate and the suture to wound length ratio for both materials (P<0·001). These results indicate that suture of midline laparotomy wounds is as safe with polydioxanone as it is with nylon. Incisional hernia is associated more with suture technique than with the material used.Keywords
This publication has 23 references indexed in Scilit:
- Suture length to wound length ratio and healing of midline laparotomy incisionsBritish Journal of Surgery, 1993
- Closure of Abdominal Wounds With PolydioxanoneArchives of Surgery, 1988
- Polydioxanone or polypropylene for closure of midline abdominal incisions: A prospective comparative clinical trialBritish Journal of Surgery, 1987
- ‘Button hole’ incisional hernia: A late complication of abdominal wound closure with continuous non-absorbable suturesBritish Journal of Surgery, 1987
- Performance of sliding knots in monofilament and multifilament suture materialObstetrics & Gynecology, 1986
- Abdominal incisions and their closureCurrent Problems in Surgery, 1985
- A COMPARISON OF UPPER ABDOMINAL WOUND CLOSURE WITH MONOFILAMENT NYLON AND POLYGLYCOLIC ACIDAnz Journal of Surgery, 1983
- Incisional hernia after mass closure of abdominal incisions with dexon and proleneBritish Journal of Surgery, 1982
- An experimental study of the relationship between synergistic wound sepsis and suture materialsBritish Journal of Surgery, 1980
- Abdominal wound closure: A trial of nylon, polyglycolic acid and steel suturesBritish Journal of Surgery, 1977