Evaluation of Serotonergic Transporters using PET and [11C](+)McN-5652: Assessment of Methods
- 1 February 2000
- journal article
- clinical trial
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 20 (2) , 253-262
- https://doi.org/10.1097/00004647-200002000-00005
Abstract
[11C](+)McN-5652 is an established positron emission tomography tracer used to assess serotonergic transporter density. Several methods have been used to analyze [11C](+)McN-5652 data; however, no evaluation of candidate methods has been published in detail yet. In this study, compartmental modeling using a one-tissue compartment model ( K1, k″2), a two-tissue compartment model ( K1 to k4), and a noncompartmental method that relies on a reference region devoid of specific binding sites were assessed. Because of its low density of serotonergic transporters, white matter was chosen as reference. Parameters related to transporter density were the total distribution volume DV″ (= K1/ k″2, one tissue compartment), DVtot (= K1/ k′1 (1 + k3/ k4), two tissue compartments), and Rv (= k′3/ k4, noncompartmental method). The DV″, DVtot, and Rv values extended over a similar range and reflected the known pattern of serotonergic transporters. However, all parameters related to transporter density were markedly confounded by nonspecific binding. With regard to K1, the one-tissue compartment model yielded markedly lower values, which were, however, more stable. The minimal study duration needed to determine stable values for the distribution volume was ∼60 minutes. The choice of the method to analyze [11C](+)McN-5652 data depends on the situation. Parametric maps of Rv are useful if no information on K1 is needed. If compartmental modeling is chosen, both the one- and the two-tissue compartment models have advantages. The one-tissue compartment model underestimates K1 but yields more robust values. The distribution volumes calculated with both models contain a similar amount of information. None of the parameters reflected serotonergic transporter density in a true quantitative manner, as all were confounded by nonspecific binding.Keywords
This publication has 16 references indexed in Scilit:
- Changes of Cerebral Blood Flow during Short-Term Exposure to Normobaric HypoxiaJournal of Cerebral Blood Flow & Metabolism, 1998
- Positron emission tomography imaging of serotonin transporters in the human brain using [11C](+)McN5652Synapse, 1995
- [11C](+)McN5652 as a radiotracer for imaging serotonin uptake sites with petLife Sciences, 1993
- Compartmental Analysis of [11C]Flumazenil Kinetics for the Estimation of Ligand Transport Rate and Receptor Distribution Using Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1991
- Quantitative in vivo analysis of benzodiazepine binding sites in the human brain using positron emission tomographyNeuropharmacology, 1991
- Graphical Analysis of Reversible Radioligand Binding from Time—Activity Measurements Applied to [N-11C-Methyl]-(−)-Cocaine PET Studies in Human SubjectsJournal of Cerebral Blood Flow & Metabolism, 1990
- Asymmetric induction in an enammonium-iminium rearrangement. Mechanistic insight via NMR, deuterium labeling, and reaction rate studies. Application to the stereoselective synthesis of pyrroloisoquinoline antidepressantsJournal of the American Chemical Society, 1990
- Regional distribution of serotonergic pre‐ and postsynaptic markers in human brainActa Psychiatrica Scandinavica, 1989
- Pyrroloisoquinoline antidepressants. 2. In-depth exploration of structure-activity relationshipsJournal of Medicinal Chemistry, 1987
- A new look at the statistical model identificationIEEE Transactions on Automatic Control, 1974