Blood Volume Measurement at the Bedside Using ICG Pulse Spectrophometry
- 1 December 1998
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 89 (6) , 1322-1328
- https://doi.org/10.1097/00000542-199812000-00008
Abstract
Background: In the treatment of critically ill patients, blood volume (BV) measurement requires injection of some tracer substance and subsequent blood sampling to analyze the tracer concentration. To obviate both the sampling and laboratory analysis, techniques of pulse oximetry have been adapted to the noninvasive optical measurement in the patient's nose or finger of the arterial concentration of an injectable dye. Methods: The authors report the clinical accuracy of a new noninvasive bedside BV measurement test that uses pulse spectrophotometry (the pulse method). The device detects pulsatile changes of tissue optical density of a nostril or a finger spanned by a probe emitting two infrared wavelengths (805 and 890 nm). After a peripheral or central intravenous injection of indocyanine green, the arterial dye concentration is continuously computed by reference to the previously measured blood hemoglobin concentration. Three types of tests of its accuracy are described here. Results: In 10 healthy volunteers, the authors compared BV determined by the pulse method with an (131)I-labeled human serum albumin method. Three subject data sets were excluded because of motion artifact, a low signal:noise ratio, or both. For the other seven volunteers, the bias+/-SD of pulse spectrophotometric BV values were 0.20+/-0.24 l (or 4.2+/-4.9%) for the nose probe and 0.34+/-0.31 l (or 7.3+/-6.9%) for the finger probe, with a mean BV of 5 l. In 30 patients who underwent cardiac surgery, the pulse method was compared with a standard indocyanine green method using intermittent blood sampling. In three patients, the BV could not be determined by the pulse method because of motion artifact, low signal:noise ratio, or both. In 27 patients, the bias+/-SD of the BV by the pulse method was -0.23+/-0.37 l (-5.3+/-8.7%) for the nose and -0.25+/-0.5 l (-4.2+/-8.4%) for the finger. Patient BV ranged from 2.51 to 7.13 l (mean, 4.48 l). In 10 additional patients before cardiac surgery, BV was measured by the pulse method before and shortly after removal of 400 ml blood. The pulse method recorded a decrease of BV of 480+/-114 mL Three days after venesection, the mean BV was 117+/-159 ml less than the predonation control. Conclusions: In most patients, the pulse method provides bedside measurement of BV without blood sampling (except for hemoglobin determination), with an estimated error less than 10%. In 10-30% of tests the method failed because of motion distortion of the record during the 10-min data collection period or because of insufficient pulse amplitude in the test tissue.Keywords
This publication has 14 references indexed in Scilit:
- Cardiac output and circulating blood volume analysis by pulse dye-densitometryJournal of Clinical Monitoring and Computing, 1997
- Determination of plasma volume with indocyanine green in manLife Sciences, 1993
- Determination of circulating blood volume by measurement of indocyanine green dye in hemolysate: A preliminary studyLife Sciences, 1990
- Differential inhibition of various deoxyribonucleic acid polymerases by Evans blue and aurintricarboxylic acidEuropean Journal of Biochemistry, 1988
- History of blood gas analysis. VII. Pulse oximetryJournal of Clinical Monitoring and Computing, 1987
- A method for measurement of total circulating blood volume using indocyanine green.The Tohoku Journal of Experimental Medicine, 1986
- Comparison of 7 azo dyes and their azo reduction products in the rat and hamster hepatocyte primary culture/DNA-repair assaysMutation Research/Genetic Toxicology, 1984
- Determination of blood volume using indocyanine green (Cardio-Green®) dyeLife Sciences, 1968
- INDOCYANINE GREEN: OBSERVATIONS ON ITS PHYSICAL PROPERTIES, PLASMA DECAY, AND HEPATIC EXTRACTION*Journal of Clinical Investigation, 1960
- CIRCULATING RED CELL VOLUME MEASURED SIMULTANEOUSLY BY THE RADIOACTIVE IRON AND DYE METHODS 1Journal of Clinical Investigation, 1946