Forces acting on the maxillary incisor teeth during laryngoscopy using the Macintosh laryngoscope
Open Access
- 1 December 1994
- journal article
- Published by Wiley in Anaesthesia
- Vol. 49 (12) , 1064-1070
- https://doi.org/10.1111/j.1365-2044.1994.tb04358.x
Abstract
We determined the forces on the maxillary incisors during routine laryngoscopy in 65 adult patients. The forces were measured by a strain gauge based sensor positioned between the handle and the blade of the laryngoscope. The mean maximal force acting on the maxillary incisors was 49 N. In patients without maxillary incisors, the force acting on the gums was significantly lower at 21N (p < 0.001). These results suggest that, despite traditional advice to the contrary, a levering movement of the laryngoscope, using the maxillary incisors (or gums) as a fulcrum, is common practice. Biomechanical analysis revealed that, although levering is not the preferred movement, it is an efficient way of bringing the glottis into view. These results may have implications for future laryngoscope design.Keywords
This publication has 15 references indexed in Scilit:
- Forces applied during laryngoscopy in childrenActa Anaesthesiologica Scandinavica, 1994
- Measurement of forces during laryngoscopyAnaesthesia, 1992
- Force Applied During Tracheal IntubationAnesthesia & Analgesia, 1992
- Hemodynamic and catecholamine responses to laryngoscopy with vs. without endotracheal intubationActa Anaesthesiologica Scandinavica, 1991
- Rapid-Sequence Orotracheal IntubationAnesthesiology, 1990
- Laryngoscope design and the difficult adult tracheal intubationCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1989
- Dental Damage during Anaesthesia and SurgeryAnaesthesia and Intensive Care, 1987
- Rapid Tracheal Intubation with VecuroniumAnesthesiology, 1985
- Difficult tracheal intubation in obstetricsAnaesthesia, 1984
- A measuring laryngoscope handle: a device for measuring the forces applied during laryngoscopyMedical & Biological Engineering & Computing, 1983