Assessing the Dynamic Range and Peak Capacity of Nanoflow LC−FAIMS−MS on an Ion Trap Mass Spectrometer for Proteomics
- 12 August 2008
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (18) , 6888-6897
- https://doi.org/10.1021/ac8004988
Abstract
Proteomics experiments on complex mixtures have benefited greatly from the advent of fast-scanning ion trap mass spectrometers. However, the complexity and dynamic range of mixtures analyzed using shotgun proteomics is still beyond what can be sampled by data-dependent acquisition. Furthermore, the total liquid chromatography−mass spectrometry (LC−MS) peak capacity is not sufficient to resolve the precursors within these mixtures, let alone acquire tandem mass spectra on all of them. Here we describe the application of a high-field asymmetric waveform ion mobility spectrometry (FAIMS) device as an interface to an ion trap mass spectrometer. The dynamic range and peak capacity of the nanoflow LC−FAIMS−MS analysis was assessed using a complex tryptic digest of S. cerevisiae proteins. By adding this relatively simple device to the front of the mass spectrometer, we obtain an increase in peak capacity >8-fold and an increase in dynamic range of >5-fold, without increasing the length of the LC−MS analysis. Thus, the addition of FAIMS to the front of a table-top mass spectrometer can obtain the peak capacity of multidimensional protein identification technology (MudPIT) while increasing the throughput by a factor of 12.Keywords
This publication has 49 references indexed in Scilit:
- Performance Characteristics of Electron Transfer Dissociation Mass SpectrometryMolecular & Cellular Proteomics, 2007
- High-Speed Data Reduction, Feature Detection, and MS/MS Spectrum Quality Assessment of Shotgun Proteomics Data Sets Using High-Resolution Mass SpectrometryAnalytical Chemistry, 2007
- A Platform for Accurate Mass and Time Analyses of Mass Spectrometry DataJournal of Proteome Research, 2007
- Multiplexed Ion Mobility Spectrometry-Orthogonal Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2007
- Supplemental Activation Method for High-Efficiency Electron-Transfer Dissociation of Doubly Protonated Peptide PrecursorsAnalytical Chemistry, 2006
- High-Resolution Field Asymmetric Waveform Ion Mobility Spectrometry Using New Planar Geometry AnalyzersAnalytical Chemistry, 2006
- Mapping the Proteome ofDrosophilamelanogaster: Analysis of Embryos and Adult Heads by LC−IMS−MS MethodsJournal of Proteome Research, 2005
- Systematic Comparison of a Two-dimensional Ion Trap and a Three-dimensional Ion Trap Mass Spectrometer in ProteomicsMolecular & Cellular Proteomics, 2005
- An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein databaseJournal of the American Society for Mass Spectrometry, 1994
- A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric fieldInternational Journal of Mass Spectrometry and Ion Processes, 1993