Application of Fiberoptics to the Clinical Measurement of Intra‐Uterine Pressure in Labor
- 11 January 1986
- journal article
- research article
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 65 (6) , 551-555
- https://doi.org/10.3109/00016348609158385
Abstract
In the present report we describe a new technique for monitoring intra‐uterine pressures during labor. the method utilizes a fiberoptic pressure transducer which is both accurate and stable. the pressure sensor is located at the catheter tip thus eliminating hydrostatic errors during monitoring. At body temperature the catheter is soft and flexible and represents no harm to the fetus. the membrane is housed in a metal dome with large lateral apertures. This arrangement greatly reduces the possibility of blockage. A comparison was made between recordings from the fiberoptic pressure transducer and those from a fluid‐filled catheter implanted simultaneously in non‐selected subjects during labor. Close agreement was obtained in the majority of cases. Large discrepancies between the two techniques were assumed to reflect the fact that the precise measuring point is not identical in each system. to date, recordings have been made in 52 parturients with no problems with insertion of the device and without any indication of equipment malfunction.Keywords
This publication has 9 references indexed in Scilit:
- Observations on intra-uterine resting-phase pressure in at term pregnancy in different body positionsEuropean Journal of Obstetrics & Gynecology and Reproductive Biology, 1983
- A fiberoptic micro-tip pressure transducer for medical applicationsSensors and Actuators, 1983
- Fiber-optic sensors for medical and electrotechnical applications using bifurcated fiber bundlesPublished by Optica Publishing Group ,1981
- THE USE OF CATHETER‐TIP PRESSURE TRANSDUCERS FOR THE MEASUREMENT OF INTRAUTERINE PRESSURE IN LABOURBJOG: An International Journal of Obstetrics and Gynaecology, 1978
- BACTERIAL MOTILITY AND INTRAUTERINE CATHETER‐BORNE INFECTIONBJOG: An International Journal of Obstetrics and Gynaecology, 1977
- EXPERIMENTS IN THE MEASUREMENT OF INTRAUTERINE PRESSUREBJOG: An International Journal of Obstetrics and Gynaecology, 1976
- Fetal monitoring: Its effect on the perinatal mortality and cesarean section rates and its complicationsAmerican Journal of Obstetrics and Gynecology, 1975
- UTERINE ACTIVITY IN lNDUCED LABOURBJOG: An International Journal of Obstetrics and Gynaecology, 1975
- Validity of Intrauterine Pressure Measurements with Transcervical Intra-Amniotic Catheters and an Intra-Amniotic Miniature Pressure Transducer during LaborGynecologic and Obstetric Investigation, 1972