Cardiac output assessed by arterial thermodilution during exsanguination and fluid resuscitation: experimental validation against a reference technique
- 1 May 2002
- journal article
- research article
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 19 (5) , 337-340
- https://doi.org/10.1097/00003643-200205000-00004
Abstract
Background and objective: The arterial thermodilution technique offers the ability to measure cardiac output using only central venous and arterial catheters. However, the technique has been reported to overestimate cardiac output because of a higher loss of cold indicator due to the increased distance between the sites of injection and measurement. In this study, the two techniques were compared with respect to conditions of low cardiac output in which a longer passage time may further increase loss of indicator. Methods: Seventeen anaesthetized dogs were studied during hypovolaemic shock and fluid resuscitation. Cardiac output measurements were carried out simultaneously by arterial and pulmonary artery thermodilution techniques. Results: One-hundred-and-two measurements were performed. The mean cardiac output was 2.28 ± 1.4 L min−1 by the pulmonary arterial technique and 2.29 ± 1.56 L min−1 by the arterial thermodilution technique. The correlation coefficient between the two measurements was 0.95, the precision −0.04 ± 0.41 L min−1 and the limits of agreement from −0.86 to 0.78 L min−1. The agreement was also consistent at low cardiac outputs. Conclusions: The arterial thermodilution technique may serve as a less invasive cardiac output monitor in conditions of severe bleeding and shock.Keywords
This publication has 14 references indexed in Scilit:
- Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilutionCritical Care Medicine, 1999
- Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass graftingJournal of Cardiothoracic and Vascular Anesthesia, 1999
- Lithium dilution cardiac output measurementCritical Care Medicine, 1997
- A comparison of hemodynamic parameters derived from transthoracic electrical bioimpedance with those parameters obtained by thermodilution and ventricular angiographyCritical Care Medicine, 1997
- Whole-body impedance cardiography in the measurement of cardiac outputCritical Care Medicine, 1997
- HZV-Bestimmung mittels transpulmonaler Thermodilution Eine Alternative zum Pulmonaliskatheter? (Cardiac output measurement by transpulmonary indicator dilution technique)Der Anaesthesist, 1996
- The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III PatientsJAMA, 1996
- Improvement of cardiac output estimation by the thermodilution method during mechanical ventilationIntensive Care Medicine, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- THE MEASUREMENT OF EXTRAVASCULAR LUNG WATER BY THERMAL‐GREEN DYE INDICATOR DILUTION*Annals of the New York Academy of Sciences, 1982