Velocity‐encoded, phase‐difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy on the number of cine frames
- 1 September 1996
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 6 (5) , 733-742
- https://doi.org/10.1002/jmri.1880060506
Abstract
Phase-contrast magnetic resonance imaging (PC-MRI) can be used to produce multiframe cine flow images of the coronary arteries. Accurate coronary flow measurement requires the elimination of respiratory motion artifacts using k-space segmentation to acquire the data in a single breath-hold. However, the duration of the breath-hold is proportional to the number of cine frames. In the present study, the number of cine frames was varied and the accuracies of the coronary flow measurements were assessed using perivascular US. For the range of flows studied (2 ml/min to 147 ml/min), the correlation coefficients for PC-MRI and US increased (.70–.98) and the limits of agreement improved (±45 ml · min−1 to ± 10 ml · min−1) as the number of cine frames increased from one to six. The results suggest that the accuracy of breath-hold cine PC-MRI measurements of coronary artery flow improves as the number of cine frames increases.Keywords
This publication has 40 references indexed in Scilit:
- Coronary flow dynamics and reserve assessed by transesophageal echocardiography in obstructive hypertrophic cardiomyopathyThe American Journal of Cardiology, 1994
- Interleaved echo planar flow quantitationMagnetic Resonance in Medicine, 1994
- Simultaneous Detection of Multiple Components of Motion with MRIJournal of Computer Assisted Tomography, 1994
- Assessing the hemodynamic significance of coronary artery stenosis: Analysis of translesional pressure-flow velocity relations in patientsJournal of the American College of Cardiology, 1993
- Encoding strategies for three‐direction phase‐contrast MR imaging of flowJournal of Magnetic Resonance Imaging, 1991
- In Vivo Validation of MR Velocity ImagingJournal of Computer Assisted Tomography, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Maximal coronary flow and the concept of coronary vascular reserve.Circulation, 1984
- Physiologic basis for assessing critical coronary stenosisThe American Journal of Cardiology, 1974
- Testing of an improved ultrasound flowmeter: technical description and results of testing in vitroCardiovascular Research, 1970