A Quantitative Study of Ramped Radio Frequency, Magnetization Transfer, and Slab Thickness in Three-Dimensional Time-of-Flight Magnetic Resonance Angiography in a Patient Population
- 1 June 1996
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 31 (6) , 323-332
- https://doi.org/10.1097/00004424-199606000-00003
Abstract
The authors compare the effectiveness of various magnetic resonance (MR) angiography acquisition strategies in enhancing the visibility of small intracranial vessels. Blood vessel contrast-to-noise ratio (CNR) in time-of-flight MR angiography was studied as a function of vessel size and several selectable imaging parameters. Contrast-to-noise measurements were made on 257 vessel segments ranging in size from 0.3 mm to 4.2 mm in patients who recently had undergone intraarterial cerebral angiography. Imaging parameters studied included magnetization transfer, spatially variable radio frequency (RF) pulse profile (ramped RF), and imaging slab thickness. The combination of thin slabs (16 slices/slab), ramped RF, and magnetization transfer resulted in the highest CNR for all but the smallest vessel sizes. The smallest vessels (< 0.5 mm) had the highest CNR, using the thick slab (64 slices/slab) with ramped RF and magnetization transfer. Magnetization transfer always improved vessel CNR, but the improvement diminished as the slab thickness was reduced. The CNR increased with a decrease in slab thickness for all but the smallest vessel sizes. Overall, the results provide a quantitative demonstration that inflow enhancement of blood is reduced for small vessels. Thus, whereas magnetization transfer is important at all vessel sizes, it becomes the primary factor in improving the visibility of the smallest vessels.Keywords
This publication has 13 references indexed in Scilit:
- Experimental and theoretical studies of vessel contrast-to-noise ratio in intracranial time-of-flight MR angiographyJournal of Magnetic Resonance Imaging, 1996
- Optimizing three-dimensional time-of-flight MR angiography with variable repetition time.Radiology, 1994
- Contrast-to-Noise-Ratio Measurements in Three-Dimensional Magnetic Resonance AngiographyInvestigative Radiology, 1993
- Improved time-of-flight MR angiography of the brain with magnetization transfer contrast.Radiology, 1992
- Magnetization transfer time‐of‐flight magnetic resonance angiographyMagnetic Resonance in Medicine, 1992
- Volume rendering and connectivity algorithms for MR angiographyMagnetic Resonance in Medicine, 1991
- MR angiography by multiple thin slab 3D acquisitionMagnetic Resonance in Medicine, 1991
- Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivoMagnetic Resonance in Medicine, 1989
- Interactive display and analysis of 3-D medical imagesIEEE Transactions on Medical Imaging, 1989
- Measurement of signal intensities in the presence of noise in MR imagesMedical Physics, 1985