Miniaturized Biosensors Employing Electropolymerized Permselective Films and Their Use for Creatinine Assays in Human Serum
- 1 November 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (21) , 3832-3839
- https://doi.org/10.1021/ac960239r
Abstract
Miniaturized, disposable amperometric biosensors for determination of creatinine in human serum are described. The base electrodes are fabricated using microelectronics techniques, to build a multilayer film structure on a polyimide foil. By using a thin electropolymerized film of poly(1,3-diaminobenzene), the electrochemical interferences from ascorbate, urate, acetaminophen, and other oxidizable species are greatly diminished. The multienzyme system (creatininase, creatinase, sarcosine oxidase) is immobilized on top of the permselective layer using cross-linking of the proteins with glutaraldehyde. The electropolymerization conditions for obtaining almost ideal permselectivity of the inner layer are defined, as well as the optimal enzyme layer preparation. A composite polymeric outer membrane [Nafion + poly-(2-hydroxyethyl methacrylate)] is used for diffusion control and to protect the enzyme layer from fouling. The reagentless planar sensors for creatinine and creatine have fast response time (t95 = 1 min), linear response up to 1.2 mM in batch-type and 2.0 mM in flow injection analysis and a detection limit of 10−20 μM. They are applied in a differential setup for creatinine assay in control and hospital human serum samples and are suitable for incorporation in a portable analyzer.Keywords
This publication has 23 references indexed in Scilit:
- Hydrogel matrix for three enzyme entrapment in creatine/creatinine amperometric biosensingAnalytica Chimica Acta, 1996
- Microfabricated amperometric creatine and creatinine biosensorsAnalytica Chimica Acta, 1996
- Development of a needle-type biosensor for intravascular glucose monitoringAnalytica Chimica Acta, 1995
- A Polypyrrole/Three-Enzyme Electrode for Creatinine DetectionAnalytical Chemistry, 1995
- Miniaturized thin film glutamate and glutamine biosensorsBiosensors and Bioelectronics, 1995
- Carbon paste electrodes modified with enzymes, tissues, and cellsElectroanalysis, 1995
- Electropolymerized 1,3-diaminobenzene for the construction of a 1,1′-dimethylferrocene mediated glucose biosensorAnalytica Chimica Acta, 1993
- Nafion‐coated carbon fiber for acetylcholine and choline sensorsElectroanalysis, 1993
- Electropolymerized films to prevent interferences and electrode fouling in biosensorsBiosensors and Bioelectronics, 1991
- Determination of creatinine in undiluted blood serum enzymatic flow injection analysis with optosensingAnalytica Chimica Acta, 1988