Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation.
Open Access
- 1 August 1978
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 43 (2) , 242-253
- https://doi.org/10.1161/01.res.43.2.242
Abstract
The pressure-flow characteristics of 100 left circumflex stenoses in 10 chronically instrumented unsedated dogs were studied under resting conditions and during pharmacological coronary vasodilation. At rest, the pressure loss (deltaP) due to a stenosis and arterial flow velocity (V) were related by the equation, deltaP = FV + SV2, where F is the coefficient of pressure loss due to viscous friction in the stenotic segment and S is the coefficient of pressure loss due to flow separation at the diverging end of the stenosis. The linear term due to viscous friction accounted for 65% and the nonlinear term due to flow separation accounted for 35% of the total pressure loss at resting coronary flow. At peak coronary flow after coronary vasodilation, the pressure loss due to viscous friction accounted for 33% and pressure loss due to flow separation accounted for 67% of the total pressure loss. The pressure gradient-velocity relationship at high flows was characterized by the same general equation but with proportionately larger values of the coefficient S and therefore greater pressure loss associated with flow separation than predicted by the resting gradient-velocity relationship. The pressure loss predicted for high coronary flow velocities on the basis of the gradient-velocity equation at rest was only 64% of the actual experimentally observed pressure gradient at peak coronary flow. The augmented separation loss following coronary vasodilation probably was due to dilation of the epicardial artery adjacent to the fixed stenotic segment which caused more severe relative percent narrowing and a larger divergence angle at the distal end of the stenosis, the primary geometric determinants of separation losses.This publication has 13 references indexed in Scilit:
- Comparison of observer performance with 16 mm cinefluorography and 70 mm camera fluorography in coronary arteriographyThe American Journal of Cardiology, 1975
- Myocardial Blood Flow Distribution during Ischemia-Induced Coronary Vasodilation in the Unanesthetized DogJournal of Clinical Investigation, 1974
- Effects of coronary stenoses on coronary flow reserve and resistancePublished by Elsevier ,1974
- Turbulent blood flow and the effects of erythrocytesCardiovascular Research, 1974
- The relationship between coronary perfusion pressure, flow, and resistance in stenosed human coronary arteries: The critical importance of small changes in % stenosisThe American Journal of Cardiology, 1974
- Physiologic basis for assessing critical coronary stenosisThe American Journal of Cardiology, 1974
- Flow characteristics in models of arterial stenoses — II. Unsteady flowJournal of Biomechanics, 1973
- Dilatation of a Medium‐Sized Artery Immediately after Local Changes of Blood Pressure and Flow as Measured by Ultrasonic TechniqueActa Physiologica Scandinavica, 1970
- Evaluation of “coronary vasodilators” by coronary arteriographyThe American Journal of Cardiology, 1964
- FITTING EMPIRICAL DATA*Annals of the New York Academy of Sciences, 1960